30 / 38 page ![]() CS1 Ordering Guide 4:7 Current Consumption Tables The amount of current/power that can be supplied to the Modules mounted in a Rack is limited by the capacity of the Rack’s Power Supply. Consider the Current/Power Consumption When Designing the System • The total current consumption of the Modules must not exceed the maximum current for each voltage group. • The total power consumption must not exceed the maximum for the Power Supply CPU Racks and Expansion Racks The following table shows the maximum currents and power that can be supplied by Power Supplies on CPU Racks and Expansion Racks (both CS1 Expansion Racks and C200HW Expansion I/O Racks). Note: 1. When calculating current/power consumption in a CPU Rack, be sure to include the power required by the CPU Rack and CPU themselves. 2. Likewise, be sure to include the power required by the Rack itself when calculating the current/power consumption in an Expansion Rack. Power Supply Max. Current Capacity Max. Total Power C ti y 5-V group 26-V group 24-V group Consumption C200HW-PA204 4.6 A 0.6 A None 30 W C200HW-PA204S 4.6 A 0.6 A 0.8 A 30 W C200HW-PA204R 4.6 A 0.6 A None 30 W C200HW-PD204 4.6 A 0.6 A None 30 W C200HW-PA209R 9A 1.3 A None 45 W SYSMAC BUS Slave Racks The following table shows the maximum current and power supplied by Power Supplies in SYSMAC BUS Slave Racks. Note: Be sure to include the power required by the Rack itself when calculating current/power consumption. Slave Module Max. Current Capacity Max. Total Power C ti 5-V group 26-V group 24-V group Consumption C200H-RT201 (Wired) 2.7 A 0.6 A 0.3 A 28 W C200H-RT202 (Wired) 2.7 A 0.6 A None 23 W C200H-RT001-P (Fiber-optic) 2.7 A 0.6 A 0.3 A 28 W C200H-RT002-P (Fiber-optic) 2.7 A 0.6 A None 23 W Note: The current consumed by each voltage group must not exceed the maximum current shown in the table above. Be Sure Both Condition 1 and Condition 2 (Listed Below) Are Met Condition 1: Maximum Current Supply 1. Current required at 5 VDC by all Modules (A) ≤ Max. Current shown in table 2. Current required at 26 VDC by all Modules (B) ≤ Max. Current shown in table 3. Current required at 24 VDC by all Modules (C) ≤ Max. Current shown in table Condition 2: Maximum Total Current Supply 1. A × 5VDC +B × 26 VDC + C × 24 VDC ≤ Max. Power shown in table |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |