| 数据搜索系统,热门电子元器件搜索 |
|
HCPL-5301 数据表(PDF) 21 Page - AVAGO TECHNOLOGIES LIMITED |
|
|
|||||||||||||||||||||||||||||
HCPL-5301 数据表(HTML) 21 Page - AVAGO TECHNOLOGIES LIMITED |
|
21 / 21 page ![]() For product information and a complete list of distributors, please go to our website: www.avagotech.com Avago, Avago Technologies, and the A logo are trademarks of Avago Technologies Limited in the United States and other countries. Data subject to change. Copyright © 2005-2008 Avago Technologies Limited. All rights reserved. Obsoletes AV01-0551EN AV02-1360EN - June 20, 2008 IPM Dead Time and Propagation Delay Specifications The HCPL-4506 series include a Propagation Delay Differ- ence specification intended to help designers minimize “dead time” in their power inverter designs. Dead time is the time period during which both the high and low side power transistors (Q1 and Q2 in Figure 24) are off. Any overlap in Q1 and Q2 conduction will result in large cur- rents flowing through the power devices between the high and low voltage motor rails. To minimize dead time the designer must consider the propagation delay characteristics of the optocoupler as well as the characteristics of the IPM IGBT gate drive circuit. Considering only the delay characteristics of the optocoupler (the characteristics of the IPM IGBT gate drive circuit can be analyzed in the same way) it is impor- tant to know the minimum and maximum turn-on (tPHL) and turn-off (tPLH) propagation delay specifications, pref- erably over the desired operating temperature range. The limiting case of zero dead time occurs when the in- put to Q1 turns off at the same time that the input to Q2 turns on. This case determines the minimum de- lay between LED1 turn-off and LED2 turn-on, which is related to the worst case optocoupler propagation delay waveforms, as shown in Figure 25. A minimum dead time of zero is achieved in Figure 25 when the signal to turn on LED2 is delayed by (tPLH max - tPHL min) from the LED1 turn off. Note that the propagation delays used to calculate PDD are taken at equal tem- peratures since the optocouplers under consideration are typically mounted in close proximity to each other. (Specifically, tPLHmax and tPHLmin in the previous equa- tion are not the same as the tPLHmax and tPHLmin, over the full operating temperature range, specified in the data sheet.) This delay is the maximum value for the propaga- tion delay difference specification which is specified at 450 ns for the HCPL-4506 series over an operating tem- perature range of -40°C to 100°C. Delaying the LED signal by the maximum propagation delay difference ensures that the minimum dead time is zero, but it does not tell a designer what the maxi- mum dead time will be. The maximum dead time oc- curs in the highly unlikely case where one optocoupler with the fastest tPLH and another with the slowest tPHL are in the same inverter leg. The maximum dead time in this case becomes the sum of the spread inthetPLHandtPHLpropagationdelaysasshowninFigure26. The maximum dead time is also equivalent to the differ- ence between the maximum and minimum propagation delay difference specifications. The maximum dead time (due to the optocouplers) for the HCPL-4506 series is 600 ns (= 450ns - (-150 ns) ) over an operating tempera- ture range of -40°C to 100°C. |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |