23 / 28 page ![]() AD7440/AD7450A Rev. C | Page 23 of 28 MODES OF OPERATION POWER-DOWN MODE The operational mode of the AD7440/AD7450A is selected by controlling the logic state of the CS signal during a conversion. There are two possible modes of operation, normal and power- down. The point at which This mode is intended for use in applications where slower throughput rates are required; either the ADC is powered down between each conversion, or a series of conversions may be performed at a high throughput rate and the ADC is then powered down for a relatively long duration between these bursts of conversions. When the AD7440/AD7450A are in the power-down mode, all analog circuitry is powered down. To enter power-down mode, the conversion process must be interrupted by bringing CS is pulled high after the conversion has been initiated determines whether or not the device enters power-down mode. Similarly, if already in power-down, CS controls whether the devices return to normal operation or remain in power-down. These modes of operation are designed to provide flexible power management options. These options can be chosen to optimize the power dissipation/throughput rate ratio for differing application requirements. CS high anywhere after the second falling edge of SCLK and before the 10th falling edge of SCLK, as shown in Figure 42. NORMAL MODE This mode is intended for fastest throughput rate performance. The user does not have to worry about any power-up times with the AD7440/AD7450A remaining fully powered up all the time. 1 10 SCLK SDATA THREE-STATE 2 CS Figure 41 shows the general diagram of the operation of the AD7440/AD7450A in this mode. The conversion is initiated on the falling edge of CS, as described in the Serial Interface section. To ensure the part remains fully powered up, Figure 42. Entering Power-Down Mode CS must remain low until at least 10 SCLK falling edges have elapsed after the falling edge of CS Once has been brought high in this window of SCLKs, the part enters power-down, the conversion that was initiated by the falling edge of CS. CS is terminated, and SDATA goes back into three-state. The time from the rising edge of CS to SDATA three-state enabled is never greater than t 110 CS SCLK SDATA 16 4 LEADING ZEROS + CONVERSION RESULT 8 (refer to the Timing Specifications). If CS is brought high before the second SCLK falling edge, the part remains in normal mode and does not power down. This avoids accidental power-down due to glitches on the CS line. Figure 41. Normal Mode Operation If CS In order to exit this mode of operation and power up the AD7440/AD7450A again, a dummy conversion is performed. On the falling edge of is brought high any time after the 10th SCLK falling edge, but before the 16th SCLK falling edge, the part remains powered up but the conversion terminates and SDATA goes back into three-state. Sixteen serial clock cycles are required to complete the conversion and access the complete conversion result. CS, the device begins to power up and continues to power up as long as CS is held low until after the falling edge of the 10th SCLK. The device is fully powered up after 1 μs has elapsed and, as shown in CS Figure 43, valid data results from the next conversion. may idle high until the next conversion or may idle low until sometime prior to the next conversion. Once a data transfer is complete, when SDATA has returned to three-state, another conversion can be initiated after the quiet time, tQUIET, has elapsed by again bringing CS low. CS SCLK SDATA 1 10 16 1 10 16 A THIS PART IS FULLY POWERED UP WITH VIN FULLY ACQUIRED PART BEGINS TO POWER UP INVALID DATA VALID DATA tPOWER-UP Figure 43. Exiting Power-Down Mode |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |