| 数据搜索系统,热门电子元器件搜索 |
|
ADA4891-2ARZ-R7 数据表(PDF) 16 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
ADA4891-2ARZ-R7 数据表(HTML) 16 Page - Analog Devices |
|
16 / 20 page ![]() ADA4891-1/ADA4891-2 Rev. A | Page 16 of 20 LAYOUT, GROUNDING, AND BYPASSING POWER SUPPLY BYPASSING Power supply pins are additional op amp inputs, and care must be taken so that a noise-free stable dc voltage is applied. The purpose of bypass capacitors is to create a low impedance path from the supply to ground over a range of frequencies, thereby shunting or filtering the majority of the noise to ground. Bypassing is also critical for stability, frequency response, distortion, and PSRR performance. Chip capacitors of 0.1 μF (X7R or NPO) are critical and should be as close as possible to the amplifier package. The 0508 case size for such a capacitor is recommended because it offers low series inductance and excellent high frequency performance. Larger chip capacitors, such as 0.1 μF capacitors, can be shared among a few closely spaced active components in the same signal path. A 10 μF tantalum capacitor is less critical for high frequency bypassing, but does provide additional bypassing for lower frequencies. GROUNDING When possible, ground and power planes should be used. Ground and power planes reduce the resistance and inductance of the power supply feeds and ground returns. If multiple planes are used, they should be stitched together with multiple vias. The returns for the input, output terminations, bypass capacitors, and RG should all be kept as close to the ADA4891 as possible. Ground vias should be placed at the very end of the component mounting pads to provide a solid ground return. The output load ground and the bypass capacitor grounds should be returned to a common point on the ground plane to minimize parasitic inductance that can help improve distortion performance. INPUT AND OUTPUT CAPACITANCE Parasitic capacitance can cause peaking and instability and, therefore, should be minimized to ensure stable operation. High speed amplifiers are sensitive to parasitic capacitance between the inputs and ground. A few picofarads of capacitance reduces the input impedance at high frequencies, in turn increasing the gain of the amplifier and causing peaking of the frequency response or even oscillations, if severe enough. It is recommended that the external passive components, which are connected to the input pins, be placed as close as possible to the inputs to avoid parasitic capacitance. In addition, all ground and power planes under the pins of the ADA4891 should be cleared of copper to prevent parasitic capacitance between the input and output pins to ground. This is because a single mounting pad on a SOIC footprint can add as much as 0.2 pF of capacitance to ground if the ground or power plane is not cleared under the ADA4891 pins. In fact, the ground and power planes should be kept at a distance of at least 0.05 mm from the input pins on all layers of the board. INPUT-TO-OUTPUT COUPLING To minimize capacitive coupling between the inputs and output and to avoid any positive feedback, the input and output signal traces should not be parallel. In addition, the input traces should not be close to each other. A minimum of 7 mils between the two inputs is recommended. LEAKAGE CURRENTS In extremely low input bias current amplifier applications, stray leakage current paths must be kept to a minimum. Any voltage differential between the amplifier inputs and nearby traces sets up a leakage path through the PCB. Consider a 1 V signal and 100 GΩ to ground present at the input of the amplifier. The resultant leakage current is 10 pA; this is 5× the typical input bias current of the amplifier. Poor PCB layout, contamination, and the board material can create large leakage currents. Common contaminants on boards are skin oils, moisture, solder flux, and cleaning agents. Therefore, it is imperative that the board be thoroughly cleaned and the board surface be free of contaminants to take full advantage of the low input bias currents of the ADA4891. To significantly reduce leakage paths, a guard-ring/shield should be used around the inputs. The guard-ring circles the input pins and is driven to the same potential as the input signal, thereby reducing the potential difference between pins. For the guard ring to be completely effective, it must be driven by a relatively low impedance source and should completely surround the input leads on all sides, above, and below, using a multilayer board (see Figure 53). The SOT-23-5 package presents a challenge in keeping the leakage paths to a minimum. The pin spacing is very tight, so extra care must be used when constructing the guard ring (see Figure 54 for recommended guard-ring construction). NONINVERTING GUARD RING INVERTING GUARD RING Figure 53. Guard-Ring Configurations +V –IN +IN –V VOUT +V –IN +IN –V VOUT ADA4891 ADA4891 NONINVERTING INVERTING Figure 54. Guard-Ring Layout SOT-23-5 |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |