7 / 12 page ![]() ATS632LSC HALL-EFFECT GEAR-TOOTH SENSOR SUBASSEMBLY APPLICATIONS INFORMATION Recommended Evaluation Technique. The self- calibrating feature of the ATS632LSC requires that a special evaluation technique be used to measure its high- accuracy performance capabilities. Installation inaccura- cies are calibrated out at power on; hence, it is extremely important that the device be re-powered at each air gap when gathering timing accuracy data. Self-Calibrating Functions. This subassembly is designed to minimize performance variation caused by the large air gap variations resulting from installation by self-calibrating at power-on. It is also designed to mini- mize performance variation caused by the smaller, slower air gap changes resulting from temperature change and gear run-out during continuous operation by updating the self-calibration periodically (after every 64 output pulses) if necessary. These two functions should be tested using the following procedure. 1. Set the air gap to the desired value. 2. Power down and then power on the device. 3. Rotate the target at the desired speed. 4. Wait for calibration to complete (16 output pulses to occur). 5. Monitor output for correct switching and measure accuracy. 6. Repeat the above for multiple air gaps within the operating range of the device. 7. This can be repeated over the entire temperature range. CRITERIA FOR DEVICE QUALIFICATION All Allegro sensors are subjected to stringent qualification requirements prior to being released to production. To become qualified, except for the destructive ESD tests, no failures are permitted. Test Method and Samples Qualification Test Test Conditions Test Length Per Lot Comments Temperature Humidity JESD22-A101, 1000 hrs 48 Device biased for Bias Life TA = 85°C, RH = 85% minimum power Bias Life JESD22-A108, 1000 hrs 48 TA = 150°C, TJ = 165°C (Surge Operating Life) JESD22-A108, 168 hrs 48 TA = 175°C, TJ = 190°C Autoclave, Unbiased JESD22-A102, 96 hrs 48 TA = 121°C, 15 psig High-Temperature JESD22-A103, 1000 hrs 48 (Bake) Storage Life TA = 170°C Temperature Cycle JESD22-A104 1000 cycles 48 -55 °C to +150°C ESD, CDF-AEC-Q100-002 Pre/Post 3 per Test to failure Human Body Model Reading test All leads > 8 kV |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |