| 数据搜索系统,热门电子元器件搜索 |
|
FN281-10-06 数据表(PDF) 1 Page - List of Unclassifed Manufacturers |
|
|
|||||||||||||||||||||||||||||
FN281-10-06 数据表(HTML) 1 Page - List of Unclassifed Manufacturers |
|
1 / 5 page ![]() EMC/EMI Products > FN 280 Compact Filtered Power Entry Module Typical applications The FN 280 power entry module combines an IEC inlet, a mains filter with single or dual- fuse holder and a 2-pole rocker switch in a small form factor. Choosing FN 280 product line brings you the rapid availability of a standard filter associated with the necessary safety acceptances. Standard IEC connector filters are a practical solution helping you to pass EMI system approval in a short time. A wide selection on amperage ratings, fuse options, mounting possibilities and filters for medical applications are designed to offer you the desired solution. n High conducted attenuation performance, based on chokes with high saturation resistance and excellent thermal behavior. n Rear/front or snap-in mounting. n Single or dual-fuse holder. n 2-pole rocker switch. n Custom-specific versions are available on request. n Portable electrical and electronic equipment n Consumer goods n EDP and office equipment n Single-phase power supplies, switch-mode power supplies n Test and measurement equipment n Medical equipment Features and benefits Technical specifications Maximum continuous operating voltage: 250VAC, 50/60Hz Operating frequency: 50 to 400Hz Rated currents: 1 to 10A @ 40°C max. High potential test voltage: P –> PE 2000VAC for 2 sec (standard types) P –> PE 2500VAC for 2 sec (B types) P –> N 760VAC for 2 sec Protection category: IP40 according to IEC 60529 Temperature range (operation and storage): -25°C to +85°C (25/85/21) Design corresponding to: UL 1283, CSA 22.2 No. 8 1986, IEC/EN 60939 Flammability corresponding to: UL 94V-2 or better MTBF @ 40°C/230V (Mil-HB-217F): 1,500,000 hours Fuse holder: 1 or 2 fuses (Ø5 x 20mm) Marking: max. 250V ~ (text is print. below fuse symbol) Rocker switch description: Function: 2-pole, dark not illuminated Marking I - 0 Electrical specifications: Inrush current 82A 6,000 on-off operations according to UL 1054, TV 5 10,000 on-off operations according to ENEC Mechanical life: 50,000 cycles Switch ratings: USA (UL) and Canada (C-UL): 10A, 125VAC; 10A, 250VAC; 1/3HP Europe (ENEC): 10A (4A), 250VAC* * Value in () relates to the inductive current charge: cos g = 0.65 Typical electrical schematic N PE P Line Cx R 2xL1 2xCy Load N‘ PE P‘ E types Standard types N PE P Line Cx R 2xL1 2xCy Load L2 N‘ PE P‘ IEC Inlet Filters FN 280 Approvals n Rated currents up to 10A n Single or dual-fuse holder n Fuses Ø5 x 20mm n 2-pole rocker switch n General purpose application n Optional earth line choke (E type) n Optional medical version (B type) |
类似零件编号 - FN281-10-06 |
|
类似说明 - FN281-10-06 |
|
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |