13 / 19 page ![]() www.austriamicrosystems.com/DC-DC_Step-Up/AS1302 Revision 1.03 12 - 18 AS1302 Datasheet - D e t a i l e d D e s c r i p t i o n Soft-start The soft-start circuit prevents the supply from high inrush currents caused by the converter’s power-up sequence. During the soft-start (0.5ms typ) the device limits the inrush current. The device is capable to power-up at the minimum specified battery voltage and with the maximum load (ohmic equivalent) applied to the output. Undervoltage Lockout, UVLO The AS1302 is equipped with an undervoltage lockout functionality. If the battery voltage drops below 2.5V (typ) the device enters the undervoltage lockout condition. The device remains in this condition until the battery voltage is high enough to enter the soft start sequence. An internal hysteresis of 300mV prevents ringing during startup. If the input voltage increases to 2.8V (typ) again after such a condition the device turns-on automatically. Shutdown Mode The AS1302 enters low-power shutdown mode when EN is set to logic low. In shutdown the charge-pump action is halted, the output is completely disconnected from the input and VOUT will drop to 0V. Note: For a stable operation trigger at least a rising edge on the EN pin to set the internal settings of the device after VBATT power-up. Short-Circuit Protection Short-circuit protection prevents damage to the device if the output is shorted to ground. Whenever the output voltage is pulled significantly below VBATT, short-circuit protection is triggered and limits the current. As soon as VOUT recovers the protection is released and the device enters soft-start mode. Thermal Shutdown The AS1302 offers thermal shutdown, which prevents damage due to an over-temperature condition. Thermal shutdown will be initiated if the junction temperature exceeds 145°C. If the temperature drops below this value, the thermal shutdown will be released automatically and the device resumes operation. A hysteresis prevents the thermal shutdown from oscillating. Efficiency Consideration In the 2:3 operation mode the input current of the charge pump is approximately 1.5x the load current. In an ideal charge pump the efficiency can be calculated by: The same works for the 1:2 operation mode. The input current of the charge pump is approximately 2x the load current. The efficiency of a charge pump in 1:2 operation mode can be calculated by: For typical and high output power conditions the quiescent current and the switching losses are negligible and (EQ 1) and (EQ 2) are valid. Hence, with the same input Voltage the 2:3 operation mode will result into a higher efficiency than the 1:2 operation mode. (EQ 1) η P OUT P IN ------------- V OUT I OUT × V BATT 15I OUT , × ------------------------------------------- V OUT 15V , BATT ------------------------- == = (EQ 2) η P OUT P IN ------------- V OUT I OUT × V BATT 2I OUT × ------------------------------------- V OUT 2V BATT ------------------- == = |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |