| 数据搜索系统,热门电子元器件搜索 |
|
AS8222 数据表(PDF) 21 Page - ams AG |
|
|
|||||||||||||||||||||||||||||
AS8222 数据表(HTML) 21 Page - ams AG |
|
21 / 43 page ![]() AS8222 Datasheet - Detailed Descr i p ti on www.ams.com/eng/FlexRay/AS8222 Revision 1.0 20 - 42 7.3.1 NORMAL Mode In this mode the transceiver is able to send and receive data signals on the bus. TxEN and BGE control the state of the transmitter. INH1 and INH2 outputs are set high. RxD shows the bus data and RxEN the bus state. The error read out mechanism is enabled. In this mode the transmitter state can be selected as shown in Table 17. In case the over-temperature flag is set the transmitter is disabled. The bus wires are terminated to VCC/2 via receiver input resistances. If the differential bus voltage is higher than VBUSActivehigh or lower than VBUSActivelow for a time longer than tBUSActiveDetection, then activity is detected on the bus (Bus = active), RxEN is switched to logical “low” and RxD is released. If after the activity detection, the differential bus voltage is higher than VData1, RxD is high. If after the activity detection, the differential bus voltage is lower than VData0, RxD is low. If the absolute differential bus voltage is lower than VBUSActivehigh and higher than VBUSActivelow for a time longer than tBUSIdleDetection, then idle is detected on the bus (Bus = idle), RxEN and RxD are switched to logical “high”. 7.3.2 RECIEVE-ONLY Mode In this mode the transceiver has the same behavior as in NORMAL mode but the transmitter is disabled. 7.3.3 STANDBY Mode In this mode the transceiver is not able to send and receive data signals to and from the bus, but the wake up detector is active. The power consumption is significantly reduced with respect to the non-low-power operation modes. RxD, RxEN signals the negation of the wake-up flag. INH1 is set to high. If wake-up flag is set then INH2 is high, otherwise it is floating. The error read out mechanism is not enabled. The bus wires are terminated to GND (bus state: Idle_LP). 7.3.4 GO-TO-SLEEP Mode In this mode the transceiver has the same behavior as in STANDBY mode but if this mode is selected for a time longer than tSLEEP and the wake flag is cleared the device enters into the SLEEP mode. 7.3.5 SLEEP Mode In this mode the transceiver has the same behavior as in standby mode but INH1 and INH2 are floating. 7.4 Non-Operating Modes The AS8222 provides the following non-operating mode: POWER-OFF 7.4.1 POWER-OFF Mode In this mode the transceiver is not able to operate. RxD, RxEN are set to high and ERRN is set to low. INH1 and INH2 are floating. The bus wires are not connected to GND (bus state: Idle_HZ). 7.5 Undervoltage Events The device monitors the following three voltage supplies: VBAT:Battery supply voltage VIO: Supply voltage for I/O digital level adaptation VCC: Supply voltage (+5V) Table 17. Transmitter States BGE TxEN TxD Transmitter State Bus state H L H Enabled Data_1 (BP is driven high, BM is driven low) H LLEnabled Data_0 (BP is driven low, BM is driven high) X H X Disabled Idle (BP and BM are not driven) L X X Disabled Idle (BP and BM are not driven) |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |