| 数据搜索系统,热门电子元器件搜索 |
|
NISCXI-1122 数据表(PDF) 7 Page - National Instruments Corporation |
|
|
|||||||||||||||||||||||||||||
NISCXI-1122 数据表(HTML) 7 Page - National Instruments Corporation |
|
7 / 9 page ![]() 194 National Instruments • Tel: (800) 433-3488 • Fax: (512) 683-9300 • info@ni.com • ni.com Every Measurement Counts There is no room for error in your measurements. From sensor to software, your system must deliver accurate results. NI provides detailed specifications for our products so you do not have to guess how they will perform. Along with traditional data acquisition specifications, our E Series multifunction data acquisition (DAQ) devices and SCXI signal conditioning modules include accuracy tables to assist you in selecting the appropriate hardware for your application. To calculate the accuracy of NI measurement products, visit ni.com/accuracy Absolute Accuracy Absolute accuracy is the specification you use to determine the overall maximum tolerance of your measurement. Absolute accuracy specifications apply only to successfully calibrated DAQ devices and SCXI modules. There are four components of an absolute accuracy specification: • Percent of Reading – is a gain uncertainty factor that is multiplied by the actual input voltage for the measurement. • Offset – is a constant value applied to all measurements. • System Noise – is based on random noise and depends on the number of points averaged for each measurement (includes quantization error for DAQ devices). • Temperature Drift – is based on variations in your ambient temperature. • Input Voltage – the absolute magnitude of the voltage input for this calculation. The fullscale voltage is most commonly used. Based on these components, the formula for calculating absolute accuracy is: Absolute Accuracy = ±[(Input Voltage X % of Reading) + (Offset + System Noise + Temperature Drift)] Absolute Accuracy RTI1 = (Absolute Accuracy Input Voltage) 1RTI = relative to input Temperature drift is already accounted for unless your ambient temperature is outside 15 to 35 °C. For instance, if your ambient temperature is at 45 °C, you must account for 10 °C of drift. This is calculated by: Temperature Drift = Temperature Difference x % Drift per °C x Input Voltage Absolute Accuracy for DAQ Devices Absolute Device Accuracy at Full Scale is a calculation of absolute accuracy for DAQ devices for a specific voltage range using the maximum voltage within that range taken one year after calibration, the Accuracy Drift Reading, and the System Noise averaged value. Below is the Absolute Accuracy at Full Scale calculation for the NI PCI-6052E DAQ device after one year using the ±10 V input range while averaging 100 samples of a 10 V input signal. In all the Absolute Accuracy at Full Scale calculations, we assume that the ambient temperature is between 15 and 35 °C. Using the Absolute Accuracy table on the next page, we see that that the calculation for the ±10 V input range for Absolute Accuracy at Full Scale yields 4.747 mV. This calculation is done using the parameters in the same row for one year Absolute Accuracy Reading, Offset and Noise + Quantization, as well as a value of 10 V for the input voltage value. You can then see that the calculation is as follows: Absolute Accuracy = ±[(10 X 0.00037) + 947.0 µV + 87 µV] = ±4.747 mV In many cases, it is helpful to calculate this value relative to the input (RTI). Therefore, you do not have to account for different input ranges at different stages of your system. Absolute Acuracy RTI = (±0.004747/10) = ±0.0475% The following example assumes the same conditions except that the ambient temperature is 40 °C. You can begin with the calculation above and add in the Drift calculation using the % Drift per °C from Table 2 on page 196. Absolute Accuracy = 4.747 mV + ((40 – 35 °C) x 0.000006 /°C X 10 V) = ±5.047 mV Absolute Acuracy RTI = (±0.005047/10) = ±0.0505% Absolute Accuracy for SCXI Modules Below is an example for calculating the absolute accuracy for the NI SCXI-1102 using the ±100 mV input range while averaging 100 samples of a 14 mV input signal. In this calculation, we assume the ambient temperature is between 15 and 35 °C, so Temperature Drift = 0. Using the accuracy table on page 313, you find the following numbers for the calculation: Input Voltage = 0.014 % of Reading Max = 0.02% = 0.0002 Offset = 0.000025 V System Noise = 0.000005 V Absolute Accuracy = ±[(0.014 x 0.0002) + 0.000025 + 0.000005] V = ±32.8 µV Absolute Accuracy RTI = ±(0.0000328 / 0.014) = ±0.234 % The following example assumes the same conditions, except the ambient temperature is 40 °C. You can begin with the Absolute Accuracy calculation above and add in the Temperature Drift. Absolute Accuracy = 32.8 µV + (0.014 x 0.000005 + 0.000001) x 5 = ±38.15 µV Absolute Accuracy RTI = ±(0.00003815 / 0.014) = ±0.273 % Multifunction DAQ and SCXI Signal Conditioning Accuracy Specifications Overview |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |