| 数据搜索系统,热门电子元器件搜索 |
|
CS5360 数据表(PDF) 13 Page - Cirrus Logic |
|
|
|||||||||||||||||||||||||||||
CS5360 数据表(HTML) 13 Page - Cirrus Logic |
|
13 / 22 page ![]() CS5360 DS280PP2 13 4.2 Bar Graph Mode This mode provides a decoded output format which indicates the peak Peak Signal Level in a "Bar Graph" format. 4.3 Overflow Overflow indicates analog input overrange for the Left and Right channels as of the last update re- quest on the Peak Update pin. A value of 1 indi- cates an overrange condition. The left channel information is output on OVFL during the left channel portion of LRCK. The right channel infor- mation is available on OVFL during the right chan- nel portion of LRCK. 4.4 Initialization Upon initial power-up, the digital filters and delta- sigma modulators are reset and the internal voltage reference is powered down. The CS5360 will re- main in the power-down mode until valid clocks are presented. A valid MCLK is required to exit power-down in Master Mode. However, in Slave Mode, MCLK and LRCK of the proper ratio are re- quired to exit power-down. MCLK occurrences are also counted over one LRCK period to determine the MCLK / LRCK frequency ratio in Slave Mode. Power is then applied to the internal voltage refer- ence, the analog inputs will move to approximately 2.2 V and output clocks will begin (Master Mode only). This process requires 32 periods of LRCK and is followed by the initialization sequence. 4.5 Initialization with High Pass Filter Enabled 28,672 LRCK cycles are required for the initializa- tion sequence with the high pass filter enabled. This time is dominated by the settling time required for the high pass filter. 4.6 Initialization and Internal Calibration with High Pass Filter Disabled If the HP DEFEAT pin is high (high pass filter dis- abled) during the initialization sequence, the CS5360 will perform an internal dc calibration by: 1) disconnecting the internal ADC inputs from the input pins, 2) connecting the (differential) ADC inputs to a common reference voltage, 3) running the high pass filter with a fast settling time constant, 4) freezing the dc offset register, and 5) reconnecting the internal ADC inputs to the in- put pins. This procedure takes 4,160 cycles of LRCK. Un- like the system calibration procedure described in the High Pass Filter section, a dc calibration per- formed during start-up will only eliminate offsets internal to the CS5360, and should result in output codes which accurately reflect the differential dc signal at the pins. Input Level P7 - P0 Overflow 11111111 0 dB to -3 dB 01111111 -3 dB to -6 dB 00111111 -6 dB to -10 dB 00011111 -10 dB to -20 dB 00001111 -20 dB to -30 dB 00000111 -30 dB to -40 dB 00000011 -40 dB to -60 dB 00000001 < - 60 dB 00000000 Table 4. P7 to P0 - Peak Signal Level Bits -Bar Graph Mode |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |