| 数据搜索系统,热门电子元器件搜索 |
|
TS117LP 数据表(PDF) 4 Page - Clare, Inc. |
|
|
|||||||||||||||||||||||||||||
TS117LP 数据表(HTML) 4 Page - Clare, Inc. |
|
4 / 8 page ![]() www.clare.com 4 TS117L Rev. 4 PERFORMANCE DATA* The Performance data shown in the graphs above is typical of device performance. For guaranteed parameters not indicated in the written specifications, please contact our application department. TS117L Typical LED Forward Voltage Drop (N=50 Ambient Temperature = 25 °C) IF = 5mADC 35 30 25 20 15 10 5 0 1.3625 1.4875 1.6125 1.7375 1.8625 LED Forward Voltage Drop (V) TS117L Typical On-Resistance Distribution (N=50 Ambient Temperature = 25 °C) (Load Current = 120mADC; IF = 2mADC) 35 30 25 20 15 10 5 0 17.0 18.2 19.0 17.8 18.6 On-Resistance ( Ω) 17.4 TS117L Typical Blocking Voltage Distribution (N=50 Ambient Temperature = 25 °C) 35 30 25 20 15 10 5 0 376.25 389.25 402.25 382.75 395.75 415.25 Blocking Voltage (V) 408.75 TS117L Typical IF for Switch Operation (N=50 Ambient Temperature = 25 °C) (Load Current = 120mADC) 0.75 1.35 1.95 0.45 1.05 1.65 2.25 LED Current (mA) 25 20 15 10 5 0 TS117L Typical IF for Switch Dropout (N=50 Ambient Temperature = 25 °C) (Load Current = 120mADC 25 20 15 10 5 0 0.75 1.35 1.95 0.45 1.05 1.65 2.25 LED Current (mA) ) TS117L Typical Turn-On Time (N=50 Ambient Temperature = 25 °C) (Load Current = 120mADC; IF = 2mADC) 0.15 0.35 0.55 0.75 0.65 0.45 0.25 Turn-On (ms) 30 25 20 15 10 5 0 TS117L Typical Turn-Off Time (N=50 Ambient Temperature = 25 °C) (Load Current = 120mADC; IF = 2mADC) 0.025 0.125 0.225 0.325 0.075 0.175 0.275 Turn-Off (ms) 35 30 25 20 15 10 5 0 TS117L Typical Load Current vs. Temperature Temperature ( °C) 180 160 140 120 100 80 60 40 20 0 -40 -20 0 20 40 60 80 120 100 10mA 5mA 2mA TS117L Typical Leakage vs. Temperature (Measured across Pins 7 & 8) Temperature ( °C) -40 0.014 0.012 0.010 0.008 0.006 0.004 0.002 -20 0 20 40 60 80 100 TS117L Typical Blocking Voltage vs. Temperature Temperature ( °C) -40 420 410 400 390 380 370 360 -20 0 20 40 60 80 100 TS117L Typical Turn-On vs. Temperature (Load Current = 120mADC) Temperature ( °C) 1.6 1.4 1.2 1.0 0.8 0.6 0.4 0.2 0 -40 -20 0 20 40 60 80 120 100 2mA 5mA 10mA 20mA TS117L Typical Turn-Off vs. Temperature (Load Current = 120mADC) Temperature ( °C) -40 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 -20 0 20 40 60 80 100 2mA 5mA |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |