数据搜索系统,热门电子元器件搜索
  Chinese  ▼
ALLDATASHEETCN.COM

X  

GX-M18A 数据表(PDF) 3 Page - Panasonic Semiconductor

部件名 GX-M18A
功能描述  Cylindrical Inductive Proximity Sensor
PDF  8 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
制造商  PANASONIC [Panasonic Semiconductor]
网页  http://www.panasonic.com/industrial/
标志 PANASONIC - Panasonic Semiconductor

GX-M18A 数据表(HTML) 3 Page - Panasonic Semiconductor

  GX-M18A Datasheet HTML 1Page - Panasonic Semiconductor GX-M18A Datasheet HTML 2Page - Panasonic Semiconductor GX-M18A Datasheet HTML 3Page - Panasonic Semiconductor GX-M18A Datasheet HTML 4Page - Panasonic Semiconductor GX-M18A Datasheet HTML 5Page - Panasonic Semiconductor GX-M18A Datasheet HTML 6Page - Panasonic Semiconductor GX-M18A Datasheet HTML 7Page - Panasonic Semiconductor GX-M18A Datasheet HTML 8Page - Panasonic Semiconductor  
Zoom Inzoom in Zoom Outzoom out
 3 / 8 page
background image
DC 3-wire type
Type
Shielded type
Non-shielded type
Normally open
GX-M8A□
GX-M12A□
GX-18A□
GX-M30A□
GX-MK12A□
GX-MK18A□
GX-MK30A□
Item
Normally closed
GX-M8B□
GX-M12B□
GX-18B□
GX-M30B□
GX-MK12B□
GX-MK18B□
GX-MK30B□
Max. operation distance (Note 2,3) 1.5 mm 0.06 in ±10 % 2 mm 0.08 in ±10 %
5 mm 0.20 in ±10 % 10 mm 0.39 in ±10 % 7 mm 0.28 in ±10 % 12 mm 0.47 in ±10 % 22 mm 0.87 in ±10 %
Stable sensing range (Note 2,3)
0 to 1.2 mm
0 to 0.05 in
0 to 1.6 mm
0 to 0.06 in
0 to 4 mm
0 to 0.16 in
0 to 8 mm
0 to 0.32 in
0 to 5.6 mm
0 to 0.22 in
0 to 9.6 mm
0 to 0.38 in
0 to 17.6 mm
0 to 0.69 in
Standard sensing object
Iron sheet 8 × 8 × t 1 mm
0.32 × 0.32 × t 0.04 in
Iron sheet 12 × 12 × t 1 mm
0.47 × 0.47 × t 0.04 in
Iron sheet 18 × 18 × t 1mm
0.71 × 0.71 × t 0.04 in
Iron sheet 30 × 30 × t 1 mm
1.18 × 1.18 × t 0.04 in
Iron sheet 24 × 24 × t 1 mm
0.94 × 0.94 × t 0.04 in
Iron sheet 24 × 24 × t 1 mm
0.94 ×0.94 × t 0.04 in
Iron sheet 45 × 45 × t 1 mm
1.77 × 1.77 × t 0.04 in
Hysteresis (Note 2)
15 % or less of operation distance (with standard sensing object)
Repeatability (Note 2)
Along sensing axis: 5 % or less of operation distance
Supply voltage
12 to 24 V DC ±10 % Ripple P-P 10 % or less
Current consumption (Note 4)
10 mA or less
Output
<NPN output type>
NPN open-collector transistor
• Maximum sink current 200 mA
• Applied voltage: 24 V DC or less (between output and 0 V)
• Residual voltage 2 V or less
<PNP output type>
PNP open-collector transistor
• Maximum source current 200 mA
• Applied voltage: 24 V DC or less (between output and + V)
• Residual voltage 2 V or less
Utilization category
DC-12 or DC-13
Short-circuit protection
Incorporated
Max. response frequency
5 kHz
5 kHz
2 kHz
1 kHz
2.5 kHz
1 kHz
0.5 kHz
Operation indicator
Yellow LED (lights up when the output is ON)
Pollution degree
3 (industrial enviroment)
Protection
IP67 (IEC)
IP69K (DIN), IP68 (IEC) (2 m cable length type only) , IP67 (IEC) (M12 plug-in connector type only)
Ambient temperature
–25 to +70 °C –13 to +158 °F, Storage: –40 to +85 °C –40 to +185 °F
Ambient humidity
50 % RH or less (at +70 °C +158 °F)
EMC
EN 60947-5-2
Voltage withstandability
500 V AC for one min. between all supply terminals connected together and enclosure
Vibration resistance
10 to 55 Hz frequency, 0.5 mm 0.02 in amplitude in X, Y and Z directions for 1.5 hours each
Shock resistance
294 m/s2 acceleration (30 G approx.) in X, Y and Z directions for three times each
Sensing range variation
(Note 2)
Within ±10 % fluctuation of sensing range at +23 °C +73 °F and rated voltage in the range of
allowable temperature and supply voltage
Material
Enclosure: Brass (Nickel plated), Sensing part: PPS
Cable (except for M12 plug-in connector type)
0.44 mm2 (0.15 mm2 for
GX-M8□) 3-core cabtyre cable, 2 m 6.56 ft long
Cable extension
Extension up to total 10 m 32.80 ft is possible with 0.34 mm2, or more, cable.
Net weight
(Note 5)
2 m cable length type
40 g approx.
70 g approx.
90 g approx.
150 g approx.
75 g approx.
100 g approx.
180 g approx.
M12 plug-in connector type
15 g approx.
20 g approx.
45 g approx.
110 g approx.
25 g approx.
55 g approx.
140 g approx.
Accessories
Nut: 2 pcs.
Notes: 1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 °C +73.4 °F.
2) It is the value in state where the circumference of a detection side has a metal object.
3) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient
temperature drift and/or supply voltage fluctuation.
4) It is the leakage current when the output is in the OFF state.
5) The weight includes the weight of two nuts.
SPECIFICATIONS
Cylindrical Inductive Proximity Sensor
GX-M SERIES
9



Html Pages

1 2 3 4 5 6 7 8


数据表 下载

Go To PDF Page


链接网址



ALLDATASHEET是否为您带来帮助?  [ DONATE ] 

关于 Alldatasheet   |   广告服务   |   联系我们   |   隐私政策   |   数据表链接    |   链接交换   |   制造商名单
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com