| 数据搜索系统,热门电子元器件搜索 |
|
AS5600-ASOM 数据表(PDF) 21 Page - ams AG |
|
|
|||||||||||||||||||||||||||||
AS5600-ASOM 数据表(HTML) 21 Page - ams AG |
|
21 / 42 page ![]() ams Datasheet Page 21 [v1-00] 2014-Aug-11 Document Feedback AS5600 − Detailed Description Burn_Setting Command (MANG, CONFIG) The host microcontroller can perform a permanent writing of MANG and CONFIG with a BURN_SETTING command. To perform a BURN_SETTING command, write the value 0x40 into register 0xFF. MANG can be written only if ZPOS and MPOS have never been permanently written (ZMCO = 00). The BURN_ SETTING command can be performed only one time. Angle Programming For applications which do not use the full 0 to 360 degree angular range, the output resolution can be enhanced by programming the range which is actually used. In this case, the full resolution of the output is automatically scaled to the programmed angular range. The angular range must be greater than 18 degrees. The range is specified by programming a start position (ZPOS) and either a stop position (MPOS) or the size of the angular range (MANG). The BURN_ANGLE command can be executed up to 3 times. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |