| 数据搜索系统,热门电子元器件搜索 |
|
AS1113 数据表(PDF) 13 Page - TEXAS ADVANCED OPTOELECTRONIC SOLUTIONS |
|
|
|||||||||||||||||||||||||||||
AS1113 数据表(HTML) 13 Page - TEXAS ADVANCED OPTOELECTRONIC SOLUTIONS |
|
13 / 25 page ![]() www.austriamicrosystems.com/LED-Driver-ICs/AS1113 Revision 1.04 12 - 24 AS1113 Datasheet - D e t a i l e d D e s c r i p t i o n If there are multiple AS1113s in a chain, the error flag will be gated through all devices. To get a valid result at the end of the chain, a logic 1 must be applied to the SDI input of the first device of the chain. If one device produces an error this error will show up after n*tP(I/O) + tSW(ERROR) at pin SDO of the last device in the chain. This means it is not possi- ble to identify which device in the chain produced the error. Therefore, if a global error occurs, the detailed error report can be run to identify which AS1113, or LED produced the error. Note: When no error has occurred, the detailed error report can be skipped, setting LD and subsequently OEN low. Error Detection Functions Open-LED Detection The AS1113 open-LED detection is based on the comparison between VDS and VTHL. The open LED status is aquired at the rising edge of OEN and stored internally. While detecting open-LEDs the output port must be turned on. Open LED detection can be started with 1 clock pulse during error detection mode while the output port is turned on. Note: LEDs which are turned off at test time cannot be tested and will be shown as a logic 1 in the detailed error report. Shorted-LED The AS1113 shorted-LED detection is based on the comparison between VDS and VTHH. The shortened LED status is aquired at the rising edge of OEN and stored internally. While detecting shorted-LEDs the output port must be turned on. Shorted-LED detection can be started with 2 clock pulses during error detection mode while the output port is turned on. For valid results, the voltage at OUTN0:OUTN15 must be lower then VTHH under low-current diagnostic mode operat- ing conditions. This can be achieved by reducing the VLED voltage or by adding additional diodes, resistors or LED’s. Note: LEDs which are turned off at test time cannot be tested and will be shown as a logic 1 in the detailed error report. Overtemperature Thermal protection for the AS1113 is provided by continuously monitoring the device’s core temperature. The overtem- perature status is aquired at the rising edge of OEN and stored internally. Table 6. Open LED Detection Modes Output Port State Effective Output Point Conditions Detected Open-LED Error Status Code Meaning On VDS < VTHL 0 Open Circuit On VDS > VTHL 1 Normal Table 7. Shorted LED Detection Modes Output Port State Effective Output Point Conditions Detected Shorted-LED Error Status Code Meaning On VDS > VTHH 0 Short Circuit On VDS < VTHH 1 Normal Table 8. Overtemperature Modes Output Port State Effective Output Point Conditions Detected Overtemperature Status Code Meaning Don’t Care Temperature > TOV1 0 Overtemperature Condition Don’t Care Temperature < TOV1 1 Normal |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |