| 数据搜索系统,热门电子元器件搜索 |
|
NFS110-7902P 数据表(PDF) 3 Page - Emerson Network Power |
|
|
|||||||||||||||||||||||||||||
NFS110-7902P 数据表(HTML) 3 Page - Emerson Network Power |
|
3 / 5 page ![]() Rev. 06.10.08 NFS110 Series 3 of 5 Embedded Power for Business-Critical Continuity Notes 1 Convection cooled, 80 W maximum. 2 Peak outputs lasting less than 60 seconds with duty cycle less than 10%. Total peak power must not exceed 110 W. 3 Forced air, 20 CFM at 1 atmosphere, 110 W maximum. 4 Figure is peak-to-peak. Output ripple is measured across a 50 MHz bandwidth using a 12 inch twisted pair terminated with a 47 μF capacitor. 5 Total regulation is defined at the static output regulation at 25 °C, including initial tolerance, line voltage within stated limits and output voltages adjusted to their factory settings. Also for NFS110-7902PJ, for 24 V output stated regulation IA / IB ² 5. This output will maintain ±5.0% regulation if IA ² 5 A, where IA = +5.1 V output current and IB = +24 V output current. 6 Single output models have floating outputs which may be referenced as either positive or negative. Higher voltage supplies, may be adjusted over a wide output voltage range, as long as the total output power does not exceed 80 Watts (natural convection) or 110 Watts (forced air). 7 Power fail detect not available on single output models. 8 Derating curve is application specific for ambient temperatures > 50 °C, for optimum reliability no part of the heatsink should exceed 90 °C and no semiconductor case temperature should exceed 100 °C. 9 Caution: Allow a minimum of 1 second after disconnecting the power when making thermal measurements. 10 The user should read the PSU installation instructions in conjunction with the relevant national safety regulations in order to ensure compliance. 11 Three orthogonal axes, random vibration, 10 minute test for each axis. 12 This product is only for inclusion by professional installers within other equipment and must not be operated as a stand alone product. 13 The ‘J’ suffix indicates that these parts are Pb-free (RoHS 6/6) compliant. TSE RoHS 5/6 (non Pb-free) compliant versions may be available on special request, please contact your local sales representative for details. 14 NOTICE: Some models do not support all options. Please contact your local Emerson Network Power representative or use the on-line model number search tool at http://www.powerconversion.com to find a suitable alternative. TRANSIENT RESPONSE NFS110-7901PJ +5.1 V (7.5-10 A) 150 mV peak, 1 ms recovery +12 V (2.5-5 A) 100 mV peak, 0.5 ms recovery -12 V (0.5-1 A) 100 mV peak, 0.5 ms recovery -5 V (0.5-1 A) 100 mV peak, 0.5 ms recovery NFS110-7902PJ +5.1 V (7.5-10 A) 150 mV peak, 1 ms recovery +12 V (2.5-5 A) 100 mV peak, 0.5 ms recovery -12 V (0.5-1 A) 100 mV peak, 0.5 ms recovery 24 V (1.5-3 A) 300 mV peak, 1 ms recovery NFS110-7904PJ +5.1 V (7.5-10 A) 150 mV peak, 1 ms recovery +15 V (2.5-5 A) 100 mV peak, 0.5 ms recovery -15 V (0.5-1 A) 100 mV peak, 0.5 ms recovery -5 V (0.5-1 A) 100 mV peak, 0.5 ms recovery NFS110-7905J +5.1 V (10-20 A) 250 mV peak, 1 ms recovery NFS110-7912J +12 V (4.5-9 A) 360 mV peak, 1 ms recovery NFS110-7915J +15 V (3.65-7.3 A) 450 mV peak, 1 ms recovery NFS110-7924J +24 V (2.25-4.5 A) 720 mV peak, Ordering Information Output Voltage Output Currents Ripple (4) Total Regulation (5) Model Numbers (13, 14, F) Max (1) Peak (2) Fan (3) +5.1 V 8 A 20 A 10 A 50 mV ±2.0% NFS110-7901PJ +12 V 4.5 A 9 A 5 A 120 mV ±3.0% –12 V 0.5 A 1.5 A 1 A 120 mV ±3.0% –5 V 0.5 A 1.5 A 1 A 50 mV ±3.0% +5.1 V (IA) 8 A 20 A 10 A 50 mV ±2.0% NFS110-7902PJ +24 V (IB) (6) 3.5 A 4.5 A 4.5 A 240 mV +10/–5.0% +12 V 4.5 A 9 A 5 A 120 mV ±3.0% –12 V 0.5 A 1.5 A 1 A 120 mV ±3.0% +5.1 V 8 A 20 A 10 A 50 mV ±2.0% NFS110-7904PJ +15 V 4 A 7.5 A 5 A 150 mV ±4.0% –15 V 0.5 A 1.5 A 1 A 150 mV ±3.0% –5 V 0.5 A 1.5 A 1 A 50 mV ±3.0% 12 V 7 A 9 A 9 A 120 mV ±2.0% NFS110-7912J (7,8) 15 V 5 A 7.3 A 7.3 A 150 mV ±2.0% NFS110-7915J (7,8) 24 V 3.5 A 4.5 A 4.5 A 240 mV ±2.0% NFS110-7924J (7,8) |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |