Back Button HB7121 Datasheet HTML 17Page - Hynix Semiconductor HB7121 Datasheet HTML 18Page - Hynix Semiconductor HB7121 Datasheet HTML 19Page - Hynix Semiconductor HB7121 Datasheet HTML 20Page - Hynix Semiconductor HB7121 Datasheet HTML 21Page - Hynix Semiconductor HB7121 Datasheet HTML 22Page - Hynix Semiconductor HB7121 Datasheet HTML 23Page - Hynix Semiconductor HB7121 Datasheet HTML 24Page - Hynix Semiconductor HB7121 Datasheet HTML 25Page - Hynix Semiconductor Next Button
Zoom Inzoom in Zoom Outzoom out
 21 / 29 page
background image
HB7121B
Semiconductor Inc.
CMOS IMAGE SENSOR
System IC SBU
With 8-bit ADC
This document is a general product description and is subject to change without notice. Hynix Semiconductor does not assume
any responsibility for use of circuits described. NO patent licenses are implied.
DA21000601R_1.0
- 21 -
2001 Hnix System IC SBU
When Integration Time > (EffectiveWindowHeight * Scale), next frame VSYNC does not follow immediately
after current frame’s last line has been produced. Instead, one of the following two idle time slots is inserted
according to Integration Time Mode before next frame VSYNC gets active.
< Idle Slots >
l
Line Mode: (Integration Time - EffectiveWindowHeight) * 1024 clocks
l
Pixel Mode: (Integration Time - EffectiveWindowHeight * Scale)
= (Integration Time - EffectiveWindowHeight * SensorArrayWidth) clocks
Each Frame Timing of the above cases may be decomposed into four timing segments
l
Initial Data Setup Time after ENB gets active
l
Even Line
l
Odd Line
l
Frame Transition
The subsections will describe frame timing diagram for said frame time cases, (Integration Time < Effective Window
Height * Scale) and (Integration Time > Effective Window Height * Scale)
(1) Frame Timing Diagram for Integration Time < (EffectiveWindowHeight * Scale)
Frame timing related registers are programmed to suit for the above condition as follows
RowStartAddress
= 6;
WindowHeight = 302;
ColumnStartAddress = 6;
WindowWidth = 402;
IntegrationTime = 200 [Line Mode];
EffectiveWindowHeight is “302” for (SensorArrayHeight > (RowStartAddress + WindowHeight + 1)), i.e. 314 >
(6 + 302 + 1), is met, and Scale is “1” for integration time is line mode.
Therefore, (Integration Time< EffectiveWindowHeight * Scale), i.e. 200 < 302 * 1, is met.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29


数据表 下载

Go To PDF Page


链接网址



ALLDATASHEET是否为您带来帮助?  [ DONATE ] 

关于 Alldatasheet   |   广告服务   |   联系我们   |   隐私政策   |   数据表链接    |   链接交换   |   制造商名单
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com