| 数据搜索系统,热门电子元器件搜索 |
|
TMP7 数据表(PDF) 5 Page - ABCircuits |
|
|
|||||||||||||||||||||||||||||
TMP7 数据表(HTML) 5 Page - ABCircuits |
|
5 / 10 page ![]() Turning Ideas Into Reality ABCircuits www.abcircuits.com POB 123 New Hill NC 27562 (919) 290-7104 Part Number TMP7 Copyright © 2014 ABCircuits. Revised September 2014 Page 5 of 10 Pin Description Pin # Description Pin # Description 1 FARH 28 VDD 2 SEG3B 27 POL 3 MIN- 26 SCALE 4 MAX- 25 SOUT- 5 SEG3C 24 TEMP 6 SEGLF 23 SEGLG 7 SEGLD 22 SEGLE 8 SEGLB 21 SEGLC 9 NC 20 SEGLA 10 SEG3G 19 NC 11 SEGRF 18 SEGRG 12 SEGRD 17 SEGRE 13 SEGRB 16 SEGRC 14 VSS 15 SEGRA POL Polarity input. If this pin is open or high, the “on” segments will have a high level on the SEG outputs of the chip. If this pin is low or grounded “on” segments will output as a low on the SEG pins. This pin is read once at power up and has a built in pull up resistor. TEMP This is the analog input for the temperature. A 10K precision resistor and a 10K NTC thermister are connected to this input for temperature measurement. The thermister should have a B25/B5 ratio of 3977K. These thermisters are available from Murata, Vishay, US Sensor, and other companies. This input is a sensitive analog input and should be protected from noise. This input may also be connected to any analog device with an output of 0 to VCC volts. In this case, the input must be protected from voltages greater than VCC or lower than ground. MIN- This optional input displays the lowest temperature since power was applied. If both MIN- and MAX- are low, the minimum temperature is reset to the current temperature. This input has a built in pull up resistor. This input has no effect on the serial output. MAX- This optional input displays the highest temperature since power was applied. If both MIN- and MAX- are low, the maximum temperature is reset to the current temperature. This input has a built in pull up resistor. This input has no effect on the serial output. SCALE and FARH These two inputs select the scale to be used, degrees C, degrees F, Percentage, or Raw data. These inputs have a built in pull up resistors. These inputs are read before every display update and serial output. |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |