FRS-R-9 数据表(PDF) 2 Page - Cooper Bussmann, Inc. |
|
|
|||||||||||||||||||||||||||||
FRS-R-9 数据表(HTML) 2 Page - Cooper Bussmann, Inc. |
|
2 / 2 page ![]() Fusetron® FRS-R Dual-Element, Time-Delay Fuses ⁄Ω¡º-60A Class RK5 – 600 Volt Form No. FRS-R 1/10-60 Page 1 of 2 Data Sheet: 1017 Bussmann® 7-25-03 A03014 ⁄Ω¡ºA to 30A .81" ( ± 0.008) 5" ( ± 0.31) 35A to 60A 1.06" ( ± 0.008) 5.5" ( ± 0.31) Catalog Numbers FRS-R-⁄Ω¡º FRS-R-1°Ω¡º FRS-R-8 FRS-R-⁄Ω• FRS-R-2 FRS-R-9 FRS-R-⁄fiΩ¡ºº FRS-R-2⁄Ω¢ FRS-R-10 FRS-R-¤Ω¡º FRS-R-2⁄Ω™ FRS-R-12 FRS-R-⁄Ω¢ FRS-R-2°Ω¡º FRS-R-15 FRS-R-‹Ω¡º FRS-R-3 FRS-R-17⁄Ω™ FRS-R-›Ω¡º FRS-R-3¤Ω¡º FRS-R-20 FRS-R-⁄Ω™ FRS-R-3⁄Ω™ FRS-R-25 FRS-R-flΩ¡º FRS-R-4 FRS-R-30 FRS-R-°Ω¡º FRS-R-4⁄Ω™ FRS-R-35 FRS-R-1 FRS-R-5 FRS-R-40 FRS-R-1⁄Ω• FRS-R-5flΩ¡º FRS-R-45 FRS-R-1⁄Ω¢ FRS-R-6 FRS-R-50 FRS-R-1›Ω¡º FRS-R-6⁄Ω¢ FRS-R-60 FRS-R-1⁄Ω™ FRS-R-7 — FRS-R-1flΩ¡º FRS-R-7⁄Ω™ — Fuse Reducers For Class R Fuses Desired Catalog Number Equipment Fuse (Case) (Pairs) Fuse Clips Size 600V 60A 30A No. 663-R 100A 30A No. 216-R 60A No. 616-R 200A 60A No. 626-R Dimensional Data Carton Quantity and Weight Ampere Carton Weight* Ratings Qty. Lbs. Kg. ⁄Ω¡º–15 10 0.40 0.181 17.5–30 10 0.50 0.277 35-60 10 3.10 1.406 *Weight per carton. General Information: • Provides motor overload, ground fault and short-circuit pro- tection. When used in circuits subject to surge currents such as those caused by motors, transformers and other inductive components, these fuses can be sized close to full-load amperes to give maximum overcurrent protection. • Permits the use of smaller and less costly switches. The time- delay feature makes it possible to use fuse ampere ratings which are much smaller than those of non-time-delay fuses. Considerable cost saving occurs by permitting the use of smaller size switches, panels and fuses themselves. • Provides a higher degree of short-circuit protection (greater current-limitation) in circuits in which surge currents or tempo- rary overloads occur. • Helps protect motors against burnout from overloads. • Gives motor running back-up protection to motors without extra costs. • Helps protect motors against burnout from single phasing on three phase systems. • Simplifies and improves blackout prevention (selective coordination). • Dual-element fuses can be applied in circuits subject to tem- porary motor overloads and surge currents to provide both high-performance, short-circuit and overload protection. • The overload element provides protection against low level overcurrent of overloads and will hold an overload which is five times greater than the ampere rating of the fuse for a minimum of ten seconds. Catalog Symbol: FRS-R Dual-Element, Time-Delay – 10 second (minimum) at 500% rated current Current-Limiting Ampere Rating: ⁄Ω¡º to 60A Voltage Rating: 600Vac (or less) Interrupting Rating: 200,000A RMS Sym. dc Ratings (20,000AIC @ 250Vdc) Agency Information: UL Listed, Std. 248-12, Class RK5, Guide JDDZ, File E4273 CSA Certified, C22.2 No. 248.12, Class 1422-02, File 53787 Recommended fuseblocks for Class R 600V fuses See Data Sheet: 1111 |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |