21 / 26 page ![]() AN2299 RC calibration Rev2 21/26 5 RC calibration The purpose of RC oscillator calibration is to bring the working frequency into the band of interest (4.0 < F < 4.2MHz) in order to properly set some absolute definitions of time in the device. The calibration can be obtained either by changing the value of current settling resistor which should be connected between pin CLKIN and Vss or by programming of one or two OTP bits (CRC). The first possibility allows a precise calibration to a certain value while the second one allows only coarse calibration in few steps. In general, it is not so important to have a precise frequency of a certain value as long it stays stable under temperature variation or aging. On the other hand, the value of this frequency directly influences the power constant of the meter. For example, if Rogowski coil is used, the constant C changes twice as much as frequency F (dC/C = 2dF/F) but, if CT or shunt is used, the constant C changes as frequency F (dC/C = dF/F). |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|