| 数据搜索系统,热门电子元器件搜索 |
|
AN1894 数据表(PDF) 9 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
AN1894 数据表(HTML) 9 Page - STMicroelectronics |
|
9 / 14 page ![]() 9/14 AN1894 - APPLICATION NOTE Furthermore conducted emissions were measured in neutral and line wire using peak or average detector. The measurements were performed at 230VAC input voltage and the 15V output was fully loaded by 100mA load. The presented results depicted from Figure 18 to Figure 21 show the results. For compliance with the EN 55014 standard, a small input filter (X-capacitor, common mode choke) should be added, if there is no EMI filter for the complete system. Alternatively, a double sided pcb can be used. 2.2 Inverting Converter -15V/100mA (Variant 2) 2.2.1 Operating Conditions Input Voltage range 90-264 VAC Input Voltage Frequency range 50/60 Hz Output -15V / 100mA Total Maximum Output Power 1.5W Figure 18: Phase L, average detector Figure 19: Phase L, peak detector Figure 20: Phase N, average detector Figure 21: Phase N, peak detector |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|