Back Button AN1897 Datasheet HTML 3Page - STMicroelectronics AN1897 Datasheet HTML 4Page - STMicroelectronics AN1897 Datasheet HTML 5Page - STMicroelectronics AN1897 Datasheet HTML 6Page - STMicroelectronics AN1897 Datasheet HTML 7Page - STMicroelectronics AN1897 Datasheet HTML 8Page - STMicroelectronics AN1897 Datasheet HTML 9Page - STMicroelectronics AN1897 Datasheet HTML 10Page - STMicroelectronics AN1897 Datasheet HTML 11Page - STMicroelectronics Next Button
Zoom Inzoom in Zoom Outzoom out
 7 / 17 page
background image
DocID10240 Rev 2
7/17
AN1897
Application description and design
17
For safety requirements, a leakage inductance value is 1 to 3% of the open circuit primary
inductance. A high efficiency transformer should have low inter-winding capacitance to
decrease the switching losses. Energy stored in the parasitic capacitance of the transformer
is absorbed by the VIPer22A-E cycle-by-cycle during the turn-on transition. Excess
capacitance also rings with stray inductance during switch transitions, causing noise
problems. Capacitance effects are usually the most important in the primary winding, where
the operating voltage (and consequent energy storage) is high. The primary winding should
be the first winding on the transformer. This allows the primary winding to have a short
length per turn, reducing the internal capacitance. The driven end of the primary winding
(the end connected to the drain pin) should be the beginning of the winding rather than the
end. This takes advantage of the shielding effect of the second half of the primary winding
and reduces capacitive coupling to adjacent windings. A layer of insulation between
adjacent primary windings can cut the internal capacitance of the primary winding by a four
factor, with consequent reduction of losses. A common technique for winding multiple
secondaries with the same polarity sharing a common return, is to stack the secondaries
(see Figure 6). This arrangement improves the load regulation, and reduces the total
number of secondary turns. Commonly a clamper based on an RCD network or a diode with
a Zener to clamp the rise of the drain voltage is used.
Figure 6. Multiple output winding
Figure 4. RCD clamp topology
Figure 5. Zener clamp topology



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17


数据表 下载

Go To PDF Page


链接网址



ALLDATASHEET是否为您带来帮助?  [ DONATE ] 

关于 Alldatasheet   |   广告服务   |   联系我们   |   隐私政策   |   数据表链接    |   链接交换   |   制造商名单
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com