7 / 64 page ![]() AN2644 The LLC resonant half-bridge converter 7/64 In resonant inverters (and converters too) power flow can be controlled by the switch network either by changing the frequency of the square wave voltage, or its duty cycle, or both, or by special control schemes such as phase-shift control. In this context we will focus on power flow control by frequency modulation, that is, by changing the frequency of the square wave closer to or further from the tank circuit's resonant frequency while keeping its duty cycle fixed. 2 The LLC resonant half-bridge converter 2.1 General overview According to another way of designating resonant converters, the LLC resonant half-bridge belongs to the family of multiresonant converters. Actually, since the resonant tank includes three reactive elements (Cr, Ls and Lp, shown in Figure 3), there are two resonant frequencies associated to this circuit. One is related to the condition of the secondary winding(s) conducting, where the inductance Lp disappears because dynamically shorted out by the low-pass filter and the load (there is a constant voltage a Vout across it): Equation 1 the other resonant frequency is relevant to the condition of the secondary winding(s) open, where the tank circuit turns from LLC to LC because Ls and Lp can be unified in a single inductor: Equation 2 It will be of course fR1 > fR2. Normally, fR1 is referred to as the resonance frequency of the LLC resonant tank, while fR2 is sometimes called the second (or lower) resonance frequency. The separation between fR1 and fR2 depends on the ratio of Lp to Ls. The larger this ratio is, the further the two frequencies will be and vice versa. The value of Lp/Ls (typically > 1) is an important design parameter. It is possible to show that for frequencies f > fR1 the input impedance of the loaded resonant tank is inductive and that for frequencies f < fR2 the input impedance is capacitive. In the frequency region fR2 < f < fR1 the impedance can be either inductive or capacitive depending on the load resistance R. A critical value Rcrit exists such that if R < Rcrit then the impedance will be capacitive, inductive for R> Rcrit. For a given tank circuit the value of Rcrit depends on f. More precisely, in [6] it is shown that for any tank circuit configuration (then for the LLC in particular): Equation 3 where Zo0 and Zo∞ are the resonant tank output impedances with the source input short- circuited and open-circuited, respectively. f R1 1 2 π Ls Cr ⋅ ----------------------------- = f R2 1 2 π Ls Lp + ()Cr ------------------------------------------- = R crit Zo 0 Zo∞ ⋅ = |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |