Back Button AN2443 Datasheet HTML 5Page - STMicroelectronics AN2443 Datasheet HTML 6Page - STMicroelectronics AN2443 Datasheet HTML 7Page - STMicroelectronics AN2443 Datasheet HTML 8Page - STMicroelectronics AN2443 Datasheet HTML 9Page - STMicroelectronics AN2443 Datasheet HTML 10Page - STMicroelectronics AN2443 Datasheet HTML 11Page - STMicroelectronics AN2443 Datasheet HTML 12Page - STMicroelectronics AN2443 Datasheet HTML 13Page - STMicroelectronics Next Button
Zoom Inzoom in Zoom Outzoom out
 9 / 15 page
background image
AN2443
Thermal management
9/15
4
Thermal management
The PCB includes a 14 x 53mm heatsink on both the top and bottom layers. Both heatsinks
are thermally interconnected with vias. Another via grid is placed directly under the device
exposed pad. This grid creates a low-resistive thermal connection of the device thermal slug
to the bottom copper layer. Via drill holes should be approximately 0.3mm in diameter and
the orthogonal grid approximately 1.2mm as shown in Figure 7.
Figure 7.
Thermal vias placement suggestion
5
EMC Immunity testing
The application was tested according to electromagnetic compatibility (EMC) immunity
standards IEC61000-4-4 (Fast Transient Burst) and IEC61000-4-5 (High Energy Surge).
The Fast Transient Burst test lasted approximately 1 minute with ±4 kV and a repetition rate
of 5 kHz. All channels were in Switching mode with a frequency of approximately 1Hz. The
burst signal was applied using a capacitive coupling clamp tool.
The High Energy Surge test was performed only in Differential mode (no protective GND
available). The signal was coupled by a 42
Ω impedance. The test contained five positive
and five negative discharges. The repetition rate was 1 discharge per minute.
The application worked properly during and after the tests. Table 2 shows the test results.
Application note AN2208 (see Section 7: Reference documents) provides specific
information about test setups.
Table 2.
EMC Immunity standards
Applied to/ Standard
IEC61000-4-4
IEC61000-4-5 (Differential Mode)
Supply voltage lines
± 4kV Criteria A
± 2kV Criteria A
Output port
± 4kV Criteria A
± 2kV Criteria A



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15


数据表 下载

Go To PDF Page


链接网址



ALLDATASHEET是否为您带来帮助?  [ DONATE ] 

关于 Alldatasheet   |   广告服务   |   联系我们   |   隐私政策   |   数据表链接    |   链接交换   |   制造商名单
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com