23 / 29 page ![]() AN2864 Testing the board Doc ID 15282 Rev 1 23/29 Figure 21. 2nd OCP protection tripping (VIN =115 VAC, full load before the short) In Figure 21, while the board is working in full load condition with an input voltage of 115 VAC, the secondary winding is shorted. The short on the secondary winding leads to very high drain current, which activates the 2nd OCP protection. Without this protection the converter runs continuously up to the activation of the overload protection, which requires a few tens of milliseconds, with very high currents in the power section of the VIPER17L and in the transformer Figure 22. Operating with secondary winding shorted restart mode (VIN =115 VAC, full load before the short) Ch2 = VFB Ch3 = VDRAIN Ch4 = IDRAIN Ch1 = VDD Ch2 = VFB Ch4 = IDRAIN |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|