| 数据搜索系统,热门电子元器件搜索 |
|
AN2064 数据表(PDF) 5 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
AN2064 数据表(HTML) 5 Page - STMicroelectronics |
|
5 / 14 page ![]() AN2064 - APPLICATION NOTE 5/14 Table 2: Telcordia GR1089 AC power fault test Using series overcurrent protection, two technologies are available, PTCs and fuses. PTCs are resistive elements that dissipate power when subjected to current, increasing their temperature and making their resistance quickly increase (10 Ω @ 25°C and 100kΩ @ 150°C for example). The nice feature of the PTCs is that they are resettable but they have two main drawbacks. The first drawback is its resistance and, as already mentioned, some applications like digital networks do not allow resistive el- ements. The second drawback is linked to its tolerance, which makes it difficult to achieve line equilibrium (longitudinal balancing). Fuses do not have these resistive drawbacks, making them well suited for digital applications. From the previous discussion we can conclude that the fuse must withstand first level surges for US (or A criterion for Europe) but may operate for second level surge (or B criterion). As far as the US market is concerned the fuse has to remain operational for the 10/1000µs 1kV 100A and the 2/10µs 2.5kV 500A lightning surges. It must also withstand first level AC power faults while it must operate for 277VRMS 25A and 600VRMS 60A second level AC power faults. First Level AC Power Fault Test Test Applied Voltage, 60Hz Short Circuit Current Duration 1 50VRMS 0.33A 15 minutes 2 100VRMS 0.17A 15 minutes 3 200VRMS, 400VRMS, 600VRMS 1A at 600V 60 Applications, 1 second each 4 (*) 1000VRMS 1A 60 Applications, 1 second each 5 NA NA 60 Applications, 5 second each 6 600VRMS 0.5A 30 seconds each 7 440VRMS 2.2A 5 x 2 seconds each 8 600VRMS 3A 5 x 1.1 second each 9 (*) 1000VRMS 5A 0.5 second each Second Level AC Power Fault Test 1 120VRMS, 277VRMS 25A 15 minutes 2 600VRMS 60A 5 seconds 3 600VRMS 7A 5 seconds 4 100VRMS-600VRMS 2.2A at 600V 15 minutes (*) Primary protector in place (MDF) |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |