9 / 15 page ![]() AN2456 SLIC protection 9/15 Figure 8. Tip, ring and –Vbat voltages during active mode normal polarity (ANP mode) Figure 9. TIP, RING and –Vbat voltages during Ringing mode 3.1 Lightning surge protection Since the application is dedicated to US, the protection has to be Telcordia GR1089 compliant. Also because it is only meant for intrabuilding SLICs located in RT, this protection needs only to be able to handle a 100 A (2/10 µs) current surge. Telcordia GR1089 Intrabuilding standard requires the EUT to meet First level compliance criterion for lightning tests. VTip (20 V/div) VRing (20 V/div) -Vbat (20 V/div) 0 VTip (20 V/div) VRing (20 V/div) -Vbat (20 V/div) 0 |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|