  AN4160 Datasheet HTML 1Page - STMicroelectronics AN4160 Datasheet HTML 2Page - STMicroelectronics AN4160 Datasheet HTML 3Page - STMicroelectronics AN4160 Datasheet HTML 4Page - STMicroelectronics AN4160 Datasheet HTML 5Page - STMicroelectronics AN4160 Datasheet HTML 6Page - STMicroelectronics AN4160 Datasheet HTML 7Page - STMicroelectronics AN4160 Datasheet HTML 8Page - STMicroelectronics AN4160 Datasheet HTML 9Page - STMicroelectronics Next Button
Zoom Inzoom in Zoom Outzoom out
 5 / 14 page
background image
DocID023640 Rev 2
5/14
AN4160
Description of the EMC standards for surge tests
14
2.3
Surge test levels
Surge levels should be selected according to application environment. Table 1 below
provides the different voltage levels and environment description according to
IEC61000 4 5:
Series resistance of the surge generator depends on the surge application mode:
•
When the surge is applied in differential mode (i.e. surge applied between lines), the
series resistance is 2
Ω
•
When the surge is applied in common mode (i.e. between a line and the ground),
series resistance is 12
Ω (2 Ω + 10 Ω ).
As the surge current impacts on the power rating of the protection devices, the table below
shows the maximum peak current values depending on voltage level and series resistance.
Figure 6 shows how the surge is applied to the EUT in both differential and common-mode
configurations.
Table 1. Voltage levels and environment description according to IEC61000-4-5
Class
Environment
Voltage level
0
Well protected environment, often in a special room
25 V
1
Partially protected environment
500 V
2
Electrical environment where the cables are well separated, even at
short runs
1 kV
3
Electrical environment where power and signal cables run in parallel
2 kV
4
Electrical environment where the interconnections include outdoor
cables along with the power cable, and cables are used for both
electronics and electric circuits
4 kV
5
Electrical environment for electronic equipment connected to
telecommunication cables and overhead power lines in a non-densely
populated area
Same as class 4
Table 2. Surge current vs. source impedance and surge level
Class 0
25 V
Class 1
500 V
Class 2
1 kV
Class 3
2 kV
Class 4
4 kV
R = 12
Ω
2.1 A
42 A
84 A
167 A
334 A
R = 2
Ω
12.5 A
250 A
500 A
1000 A
2000 A



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14


数据表 下载

Go To PDF Page


链接网址



ALLDATASHEET是否为您带来帮助?  [ DONATE ] 

关于 Alldatasheet   |   广告服务   |   联系我们   |   隐私政策   |   数据表链接    |   链接交换   |   制造商名单
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com