  AN437 Datasheet HTML 1Page - STMicroelectronics AN437 Datasheet HTML 2Page - STMicroelectronics AN437 Datasheet HTML 3Page - STMicroelectronics AN437 Datasheet HTML 4Page - STMicroelectronics AN437 Datasheet HTML 5Page - STMicroelectronics AN437 Datasheet HTML 6Page - STMicroelectronics AN437 Datasheet HTML 7Page - STMicroelectronics AN437 Datasheet HTML 8Page - STMicroelectronics AN437 Datasheet HTML 9Page - STMicroelectronics Next Button
Zoom Inzoom in Zoom Outzoom out
 3 / 18 page
background image
AN437
Snubber circuit functions and drawback
3/18
1.1.2
Snubber circuit benefit at TRIAC turn-off
The TRIAC turn-off behavior is characterized by the datasheet curve between the critical
rate of decrease of commutating on-state current ((dI/dt)c) and the critical rate of rise of
commutation off-state voltage ((dV/dt)c) (refer to Figure 3). These parameters are specified
for the maximum operating junction temperature (worst case).
In practice, the current waveform, and thus the slope of the decreasing current, is imposed
by the load. The user can then only limit the slope of the reapplied voltage. Indeed, by
adding an snubber circuit across the TRIAC, the circuit time response is increased and thus,
dV/dtOFF is decreased (refer to Figure 3).
Figure 3.
(dI/dt)c versus (dV/dt)c curve for Z01 standard TRIACs and snubber
circuit impact
An RC snubber circuit must be used when there is a risk of TRIAC spurious triggering, i.e.
when the dI/dtOFF -dV/dtOFF couple, measured in the application, is higher than the TRIAC
datasheet values, (dI/dt)c at a given (dV/dt)c.
Figure 4 shows the turn-off behavior of a Z0103 standard TRIAC which controls a 26 W
drain pump. Without snubber circuit and for the maximum junction temperature (110° C), a
spurious triggering appears at turn-off. Indeed, the measured (dI/dt)OFF and (dV/dt)OFF
values, equal respectively to 0.13 A/ms and 10 V/µs, are higher than the guarantee (dI/dt)c -
(dV/dt)c point (only 7 V/µs @ 0.13 A/ms, see Figure 3).
Thanks to an RC snubber circuit (10 nF and 2.7 k
Ω), the slope of the reapplied voltage can
be limited to 1.5 V/µs and thus spurious triggering at turn-off can be avoided (see Figure 3
and Figure 4).
V
T
I
T
Load
V
Mains
R
C
Area of spurious
firing at
commutation
Safe area
Operating point
with RC snubber
Operating point



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18


数据表 下载

Go To PDF Page


链接网址



ALLDATASHEET是否为您带来帮助?  [ DONATE ] 

关于 Alldatasheet   |   广告服务   |   联系我们   |   隐私政策   |   数据表链接    |   链接交换   |   制造商名单
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com