| 数据搜索系统,热门电子元器件搜索 |
|
AN1353 数据表(PDF) 9 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
AN1353 数据表(HTML) 9 Page - STMicroelectronics |
|
9 / 17 page ![]() AN1353 Sub-routines Rev 2 9/17 This sub-routine also defines if the motor must be started up. If the temperature becomes higher than ORDER 1, the compressor should be started. But, care must be taken not to start the motor if it is already ON. Otherwise, Ts could be switched on when Tr is already ON, resulting in a capacitor discharge through the two devices. Note that each evaporator temperature and potentiometer voltage measurements are refreshed every 256 cycles (by the average value of the previous 256 cycles). This means that the temperature control is acti-vated every 5 seconds. 5.2 Motor status This sub-routine defines which ACST must be triggered depending on the motor state and the order asked by the “LOADS_CONTROL” routine. This flowchart is shown on annex 4. When the motor is required to be ON, both Tr and Ts are switched on 500 ms. After that, only Tr is fired, if the motor must still be ON. In this case, the MOTOR_STATUS routine claims that the motor is in a transient state again for 500 ms. This state is used by the “CURRENT_MEASURE” sub-routine. Indeed, the current must not be measured during the first one second of operation, during which the current is high. On the other hand, if the current remains high after this one second, that means that an abnormal condition has occurred (stall rotor for example) and it is better to stop the motor. 5.3 Current measure The current measure is only performed when the motor should be ON, and if it is not at start-up transient state. At each overcurrent detection, the motor is stopped, a LED is switched on during 5 s, and, of course, the current measure is no longer performed. The overcurrent detection is, in fact, based on an average of four measures. This is done to reduce EMI noise. The over current therefore always acts with at least an 80 ms delay, because only one measure by cycle is done. The measured value is compared to the “VLIMIT” constant. A 242 value equals a voltage of 5.22 V at the in-put of the Analog to Digital Converter (for a 5.5 V supply). As the measure is achieved thanks to a 50 mOhm shunt, referenced to the Vdd, this value is similar to a 5.6 A current. Such a current means that the rotor is stalled because, in steady state, a 100-300 W compressor always sinks a current lower than 3 A. |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |