7 / 19 page ![]() AN2822 High speed internal oscillator trimming Doc ID 14983 Rev 2 7/19 The HSI frequency is evaluated from the number of pulses counted by timer TIM3 during certain calibration signal periods. For noisy mains, where positive and negative half-periods are not necessarily symmetrical, it is better to measure the whole period and not only the time difference between the rising and falling edge of the calibration signal. It is better to measure the number of HSI pulses for several sequential periods to reduce the uncertainty of the measurement. This is also recommended when using a noisy mains as the calibration signal. The input capture prescaler can be used for this purpose. It allows every 1st, 2nd, 4th, or 8th rising edge of the calibration signal to be selected which is then used to define the time interval for counting HSI pulses. In this way TIM3 is able to store information about the number of HSI pulses in the capture register at the beginning and at the end of a measurement. If required (for example, for validation purposes), the frequency of the HSI oscillator can be observed on the configurable clock output (CCO) pin. See Section 2 for an example of a simple post-processing circuit which adapts a mains signal to a square signal and converts the mains voltage to 5 V power supply voltage. 1.3 Calibration routine The calibration routine is written in ANSI C. It takes advantage of the STM8S and STM8A firmware library which is available from www.st.com. It can be simplified and optimized if needed. The software compares the number of HSI clock pulses during the certain number L of calibration period, Tcal (20 ms), with the ideal value (see equation below). Using this equation, the calibration routine software compares the ideal HSI clock pulse value (IdealCountedValue) with the nominal oscillator frequency, fHSInominal, during a defined calibration period, Tcal (20 ms), for a known number of calibration signal periods (L). Note: For example, if the nominal HSI frequency is 16 MHz, the defined calibration period, Tcal, is 20 ms (if the mains has a frequency of 50 Hz), and the known number of calibration signal periods, L, is 8 then the ideal value captured by the timer is 2 560 000 (0x271000) The calibration algorithm is described in Figure 3. Calibration starts with initialization of TIM3. The lowest frequency is set by writing MAX_TRIM_VAL to the CLK_HSITRIMR register. In this way, the trimming value is decreased in the program loop. The difference between the number of counted HSI pulses and the ideal value is compared with the previous difference, until either the current difference becomes greater than the preceding difference, or, until the minimum value MIN_TRIM_VAL is reached. If the new difference is greater than the preceding difference, the trimming value is incremented to the previous value, resulting in the optimum value for calibration. IdealCountedValue f HSI nominal T cal × L × = |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |