28 / 32 page ![]() Procedure to apply IEC 61000-4-4 bursts test UM0277 28/32 Appendix E Procedure to apply IEC 61000-4-4 bursts test To perform fast transient voltage tests in compliance with EN61000-4-4 specifications on thermostat boards connected to a compressor, a 15W light bulb and a 25W defrost resistor, we have implemented the arrangements shown in Figure 18. These arrangements ensure very stressful tests, but still comply with EN61000-4-4 specifications. These main arrangements are: ● Thermostat Board, loads and mains wires are placed 10 cm above the ground reference. ● The mains wire is shorter than 1m. ● The compressor protective earth is linked to the PE of the board through a 30cm cable. Figure 18. EN61000-4-4 test layout Each operating cycle has been tested (all loads OFF, lamp ON, Motor ON, lamp + motor ON). The burst withstanding level is in the range from 2.3kV to more than 4.5kV (maximum capability of our generator) depending on the coupling mode (to L, N, PE, etc.). |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|