| 数据搜索系统,热门电子元器件搜索 |
|
AN4232 数据表(PDF) 14 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
AN4232 数据表(HTML) 14 Page - STMicroelectronics |
|
14 / 17 page ![]() Application examples AN4232 14/17 DocID024134 Rev 2 Here is how the peripherals used are configured: 1. COMP4 is configured as follows: a) The inverting input is connected to DAC1 b) The non inverting input is connected to the Humidity sensor c) The output is connected internally to TIM4 channel 2 (configured in input capture mode). 2. TIM4 is clocked at 72 MHz and TIM4 channel 2 is configured in input capture mode to measure the time constant. 3. TIM3 is clocked at 72 MHz channel 3 and configured in PWM mode with the duty cycle at 50%. 4. DAC1 is used to set the threshold (reference) and it is equal to 2.85V. It is internally connected to COMP4 inverting input. Figure 8 shows the block diagram of the application and how the peripherals used are inter- connected. Figure 8. Block diagram of the humidity measurement application |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|