| 数据搜索系统,热门电子元器件搜索 |
|
AN4277 数据表(PDF) 5 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
AN4277 数据表(HTML) 5 Page - STMicroelectronics |
|
5 / 23 page ![]() DocID024409 Rev 2 5/23 AN4277 Break function overview 22 1 Break function overview The break function is available in TIM1, TIM8, TIM20, TIM15, TIM16 and TIM17 timers. These timers are able to generate complementary PWM signals with deadtime insertion for driving powers switches in half bridge topology. The purpose of the break function is to protect power switches driven by PWM signals generated with these timers. When triggered by a fault, the break circuitry shuts down the PWM outputs and forces them to a predefined safe state. For TIM1/8/20, there are three break inputs (BRK, BRK_ACTH and BRK2), while in TIM15/16/17 two break inputs (BRK and BRK_ACTH) are available. The BRK input can either disable the PWM outputs (inactive state) or forces them to a predefined safe state, either active or inactive, after a dead time insertion which allows to prevent any shoot-through in the half bridge. The BRK2 only disables the PWM outputs (inactive state). BRK has higher priority than BRK2. When both protections are triggered, the predefined safe state related to BRK circuitry overrides the inactive state related to the BRK2 input. Typically, a permanent magnet 3-phase brushless motor drive will use the protections as follows: • the BRK2 input as an over-current protection, opening the 6 switches from the power stage, • the BRK input for over-voltage protection, overriding the over-current and closing the 3 low-side switches to avoid current regeneration to build up bus voltage and exceed capacitors rated voltage. As an example, for a dual motor drive, comparators 1, 2 and 3 can be affected to over- current monitoring of the 3 phases of motor 1 (BRK2 input of TIM1). Comparators 4, 5 and 6 can be affected to over-current monitoring of the 3 phases of motor 2 (BRK2 input of TIM8), while comparator 7 will be used for over-voltage monitoring (driving BRK inputs of both TIM1 and TIM8). BRK_ACTH input is connected only to internal signals like CSS, PVD output and so on. For more details, refer to Section 2: Break implementation. |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |