9 / 43 page ![]() UM1542 Functional description Doc ID 023172 Rev 1 9/43 Figure 3. Hysteresis law Five temperature set points have been implemented: 1. Very low 2. Low 3. Medium 4. High 5. Very high For each temperature set point an evaporator temperature, a hysteresis, thus an upper limit and a lower limit are defined. THIGH_lim and TLOW_lim are respectively the upper and the lower limits of the hysteresis and are defined as: Equation 1 Equation 2 The compressor is switched on if the sensed temperature is above THIGH_lim, and switched off when this temperature becomes lower than TLOW_lim. When the door is open (Section 2.2.3), temperature control is not allowed, i.e. any action on TEMP+ and TEMP- has no effect. The temperature set point, or temperature order, can be set at one of the five levels by means of the two push buttons PB1 and PB2 (temperature setting push buttons) in standalone mode (see Figure 2) or by means of the GUI in PC-driven mode (Section 3.6), while the hysteresis value can only be changed using the GUI. Five LEDs - D4, D5, D6, D8, D9 (temperature setting LEDs) (Figure 2) in standalone mode, or VL, L, M, H, VH in PC GUI driven mode (Figure 7) - turn on according to the temperature set point. 2 lim _ Hysteresis e Temperatur Evaporator T HIGH + = 2 lim _ Hysteresis e Temperatur Evaporator T LOW − = |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |