41 / 48 page ![]() DocID025094 Rev 1 41/48 UM1657 SPIRIT1 WM-BUS GUI description 48 4 SPIRIT1 WM-BUS GUI description This section describes how to use the Spirit1 Wireless M-BUS-GUI. 4.1 Firmware installation The boards come preprogrammed with firmware suitable to run Spirit1 DK-GUI, in order to operate the WM-BUS GUI, it is necessary to reprogram the appropriate firmware. In order to program the correct firmware, you need to know in which band you would like to operate. The bands supported are 169 MHz and 868 MHz. Based on your choice, please follow the instructions in section 4.2.9.2 and load the firmware image …\Firmware\Binary\SPIRIT1- wmbus-gui-<band>.hex in the board to be used in conjunction with the GUI (concentrator) and load the firmware image …\Firmware\Binary\SPIRIT1-wmbus-meter-<band>.hex in the board to be used as a meter. 4.2 Detailed description The SPIRIT1 Wireless M-BUS - GUI requires only the concentrator to be connected with the PC, the meter is operated through joystick and buttons and it needs USB connection just for power. After the boards are prepared as described in section 5.1, the user can run the GUI. After running the GUI, the fol-lowing steps needs to be performed: 1. Connect the concentrator board to the PC. 2. Click the connect button, you should get the message "Connection Successful" (see Figure 30 and Figure 31) 3. Select the "Configuration" tab and click on receive all (see Figure 32) 4. Please check the parameters and in particular that "Device type" is concentrator and WM-Bus mode is S1m if you are using 868 MHz band or N1 if you are using 169 MHz band and that the "Device mode" is "Install mode". (see Figure 32) 5. Power the meter board and move the joystick down (or press the button SW1 for STEVAL-IDS001Vx). The yellow LED DL5 should be on in the concentrator board (or green LED D2 for STEVAL-IDS001Vx). 6. The meter should be now registered in the concentrator database 7. Go to the "Meters" tab and click Refresh 8. On the concentrator and meter, push the "Push_Button" button. Red LED DL3 should be now ON on both boards (press the button SW2 for STEVAL-IDS001Vx and the yellow LED D1 will turn ON). 9. Go to "Monitoring tab" and click "Auto Refresh" 10. On the meter, do the following: a) Push joystick up to increase the gas consumption. b) Push joystick right to send data to concentrator (press the button SW2 on STEVAL-IDS001Vx). 11. The data is automatically displayed in the "Monitoring" tab |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |