7 / 13 page ![]() DocID027438 Rev 1 7/13 AN4653 Cycling endurance 12 1.3 Cycling strategy 1.3.1 Cycling strategy and application temperature profile In order to ensure the safest EEPROM cycling conditions, it is recommended to evaluate the number of write cycles and the relative temperature profile of the cycling performed by the EEPROM during the life of the application, that is: Number of cycles at temp i () Max Number of cycles specified at temp i () ------------------------------------------------------------------------------------ 1 ≤ i1 = n ∑ • define the main temperature ranges at which the EEPROM is operating in the end application, • for each temperature range, estimate the number of write cycles executed for each data block, • for each data block (with different cycling profiles), calculate the cumulated cycling effect using the following equation or Table 3. If the total percentage of cumulated cycles (last row in Table 3) is lower than 100%, the data stored in the EEPROM are safely cycled. If the total percentage of cumulated cycles is above 100%, the intrinsic safe margin for cycling is exceeded and a data relocation strategy must be defined. This can be done by distributing the number of cycles over several memory locations as follows: • define a cycling limit for each data block according to the application needs and product performance (as shown in Table 3); • count the numbers of cycles executed on each data block (counter value can be stored in the EEPROM); • when the counter exceeds the defined limit, the cycled data block must be relocated to another physically independent memory address. The software developer should define this new data block to be duplicated in a location inside a different page and, when possible, not with the same byte address inside the new page. The counter itself must also be stored in a new location. Table 3. Application cycling profile evaluation(1) 1. The table can be adapted according to the temperature profile by taking care of putting down the maximum cycling for each temperature. Temperature Number of Cycles(2) 2. w and y are forecast number of cycles for a specific data block. % of the max cycling value specified in Table 2 25°C w (w/4M) x 100 = a % 85°C y (y/1.2M) x 100 = b% Total w + y (a + b) % |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |