MAX110ACAP 数据表(HTML) 16 Page - Maxim Integrated Products |
|
16 / 24 page ![]() Low-Cost, 2-Channel, ±14-Bit Serial ADCs 16 ______________________________________________________________________________________ X = Don't Care Table 3. Procedure to Calibrate the ADC 0 0 1 0 0 or 1 00 XX No Change 00 1 Performs an offset-null conversion with the internal ADC inputs shorted to the selected input channel's negative input (IN1- or IN2-). The next operation performs the first signal conversion with the new setup. 3 0 0 0 1 X 00 XX No Change 00 1 Performs a gain-calibration conversion with the null register contents as the starting value. The result is stored in the calibration register. 2 0 0 1 1 X 00 XX New Data 00 1 Sets the new conversion speed (if required) and performs an offset correction conversion with the internal ADC inputs shorted to REF-. The result is stored in the null register. (This step also selects the speed/resolution for the ADC.) 1 PD PDX NUL CAL CHS Not Used DV2 & DV4 CONV1- CONV4 Not Used N NO O--O OP P DESCRIPTION STEP CONTROL WORD X = Don't Care Table 2. Allowable Input Multiplexer Configurations Input control word is not transferred to the control register. ADC configuration remains unchanged and no new conversion starts when CS returns high. No Change No Change 0 X X X REF+ and REF- connected to the ADC inputs; gain-calibration mode selected. Autocal conversion begins when CS returns high, and the results are stored in the 16-bit I/O register. REF- REF+ 1 X 0 1 REF- connected to the ADC inputs; offset-null mode selected. Autonull conversion begins when CS returns high, and the results are stored in the null register. REF- REF- 1 X 1 1 IN2- connected to the ADC inputs; offset-null mode selected. Autonull conversion begins when CS returns high, and the results are stored in the null register. IN2- IN2- 1 1 1 0 IN1- connected to the ADC inputs; offset-null mode selected. Autonull conversion begins when CS returns high, and the results are stored in the null register. IN1- IN1- 1 0 1 0 Channel 2 connected to ADC inputs. Conversion begins when CS returns high. IN2- IN2+ 1 1 0 0 Channel 1 connected to ADC inputs. Conversion begins when CS returns high. IN1- IN1+ 1 0 0 0 DESCRIPTION ADC IN- ADC IN+ N NO O--O OP P CHS NUL CAL |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |