7 / 10 page ![]() GM1851 LINEAR INTEGRATED CIRCUIT UNISONIC TECHNOLOGIES CO., LTD 7 of 10 www.unisonic.com.tw QW-R122-007,B UL943 specifies ≤25 ms average trip time under these conditions. Calculation of Ct based upon charging currents due to normal fault only is as follows: ≤25 ms Specification -3 ms GFI turn-on time (15k and 1μF) -8 ms Potential loss of one half-cycle due to fault current sense of half-cycles only -4 ms Time required to open a sluggish circuit breaker ≤10 ms Maximum integration time that could be allowed 8 ms Value of integration time that accommodates component tolerances and other variables Ct= 1 × T V (5) Where T=integration time V=threshold voltage I=average fault current into Ct I = 120VAC(rms) RB × RN RG + RN heavy fault current generated (swamps ITH) portion of fault current shunted around GFI (6) 1 turn 1000 turns 1 2 0.91 ×× current division of input sense transformer Ct charging on half- cycles only rms to average conversion × therefore: × 120 500 0.4 1.6+0.4 1 1000 ×× 1 2 0.91 × × 0.0008 17.5 Ct = Ct = 0.01μF (7) In practice, the actual value of C1 will have to be modified to include the effects of the neutral loop upon the net charging current. The effect of neutral loop induced currents is difficult to quartile, but typically they sum with normal fault currents, thus allowing a larger value of C1. For UL943 requirements, 0.015μF has been found to be the best compromise between timing and noise. For those GFI standards not requiring grounded neutral detection, a still larger value capacitor can be used and better noise immunity obtained. The larger capacitor can be accommodated because RN and RG are not present, allowing the full fault current, I, to enter the GFI. In Figure 2, grounded neutral detection is accomplished by feeding the neutral coil with 120 Hz energy continuously and allowing some of the energy to couple into the sense transformer during conditions of neutral fault. |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |