| 数据搜索系统,热门电子元器件搜索 |
|
TLE7233G 数据表(PDF) 21 Page - Infineon Technologies AG |
|
|
|||||||||||||||||||||||||||||
TLE7233G 数据表(HTML) 21 Page - Infineon Technologies AG |
|
21 / 33 page ![]() Datasheet 21 Rev. 1.2, 2014-05-09 SPI Driver for Enhanced Relay Control SPIDER - TLE7233G Diagnostic Features 8 Diagnostic Features The SPI of TLE7233G provides diagnosis information about the device and about the load. The diagnosis information of the protective functions of channel n is latched in the diagnosis flag Dn. The open load diagnosis of channel n is latched in the diagnosis flag OLn. Both flags are cleared by INn =00B which disables the diagnosis current ID(PD) (a small pull down current) as well. Following table shows possible failure modes and the according protective and diagnostic action. j 8.1 Open Load Diagnosis timing The TLE7233G offers an open load diagnosis for each channel in OFF mode. The time td(fault) is applied to filter short time events. Figure 9 Open Load timing Failure Mode Comment Open Load or short circuit to GND Diagnosis, when channel n is switched on: INn = 01B: if input pin is high: none INn = 10B: none Diagnosis, when channel n is switched off: INn = 00B: none, diagnosis flags are cleared and the diagnosis current is switched off INn = 01B: if input pin is low, according to voltage at the output pin, the flag OLn is set after time t d(OL) INn = 11B: according to voltage level at the output pin, the flag OLn is set after time td(OL) Over temperature When over temperature occurs, the affected channel n is switched off. The according diagnosis flag Dn is set. The diagnosis flags are latched until they have been cleared by INn = 00B. The over temperature detection is active in ON-state as well as OFF-state. Over Load (Short Circuit) When over load is detected at channel n, the affected channel is switched off after time tOFF(OVL) and the dedicated diagnosis flag Dn is set. The diagnosis flags are latched until they have been cleared by INn = 00B. OpenLoad.emf IN VDS t t td(OL) OLn = 1b Open Load occures here IN VDS t t td(OL) OLn = 1b VDS(OL) Open Load occures here VDS(OL) |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |