| 数据搜索系统,热门电子元器件搜索 |
|
53262 数据表(PDF) 2 Page - Micropac Industries |
|
|
|||||||||||||||||||||||||||||
53262 数据表(HTML) 2 Page - Micropac Industries |
|
2 / 4 page ![]() Micropac Industries cannot assume any responsibility for any circuits shown or represent that they are free from patent infringement. Micropac reserves the right to make changes at any time in order to improve design and to supply the best product possible. MICROPAC INDUSTRIES, INC. MICROCIRCUITS DIVISION • 905 E. Walnut St., Garland, TX 75040 • (972) 272-3571 • Fax (972) 494-2281 www.micropac.com E-MAIL: hybridsales@micropac.com 05/16/2002 Pg. 2 of 4 53262 Short Circuit Protected Solid State Relay __________________________________________________________________________________________ ELECTRICAL SPECIFICATIONS TC = -40°C to +85°C, unless otherwise specified. Parameter Symbol Min. Typ.* Max. Unit s Test Conditions Notes INPUT CHARACTERISTICS Input Forward Voltage VF 2.0 2.7 3.8 VDC IF = 8 mA Input Reverse Breakdown Voltage VR 6 20 VDC IR = 10 µA 7 OUTPUT CHARACTERISTICS Output On-Resistance R (ON) 0.8 1.2 Ω IF = 8 mA, IO = 0.5 A Pulse width = 10 ms Duty cycle ≤ 10% 6 Output Leakage Current IO (OFF) 250 µA VF = 0.6 VDC VO = 400 VDC 6 Turn-On Time tON 8 ms Turn-Off time tOFF 2 ms Rise Time tR 6 ms Fall Time tF 1 ms IF = 8 mA IO = 0.5 A Pulse width = 10 ms Duty cycle ≤ 10% 3 & Figure 2 Over-current Limit ICL 1.1 4.5 A Over-current Trip Time tCL 1 ms VO = 54 VDC RL = 12 Ω 4 Peak Short Circuit Current ISC(PK) 15 20 A Short Circuit Shut Down Time tSC 100 µs Short-while-on @ TC = 25°C 5 & 7 COMMON CHARACTERISTICS Input-Output Leakage Current II-O 1 µA RH ≤ 45%, t = 5 s VI-O = 1000 VDC TC = 25°C 1 & 2 Thermal Resistance (junction-case) θJC 18.5 °C/W 7 * Typical values are at TC = 25°C Notes: 1. Input pins shorted together and output pins shorted together. 2. Input -output potential applied momentarily, not a steady state operating condition. 3. Rise time is measured from 10% to 90% of load current (90% to 10% of VO). Fall time is measured from 90% to 10% of load current (10% to 90% of VO). Guaranteed but not tested. 4. The minimum over-current limit occurs at Tc of 85°C. The maximum over-current limit occurs at Tc of -40°C. 5. Use 0.25 ohm sense resistor for monitoring the peak short circuit current. 6. The user should apply the appropriate transient suppression technique to the output terminals of the relay when the loads are inductive enough to generate voltage spikes. 7. Guaranteed but not tested. |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |