| 数据搜索系统,热门电子元器件搜索 |
|
TMP442 数据表(PDF) 22 Page - Texas Instruments |
|
|
|
|||||||||||||||||||||||||||||
TMP442 数据表(HTML) 22 Page - Texas Instruments |
|
22 / 29 page ![]() LAYOUT CONSIDERATIONS V+ DXP DXN GND NOTE:Useminimum5miltraceswith5milspacing. GroundorV+layer onbottomand/or top,ifpossible. 1 2 3 4 8 7 6 5 TMP441 0.1mFCapacitor V+ GND PCBVia DXP DXN A1 A0 1 2 3 4 8 7 6 5 TMP442 0.1mFCapacitor V+ GND PCBVia DXP1 DXN1 DXP2 DXN2 TMP441 TMP442 SBOS425A – DECEMBER 2008 – REVISED MARCH 2009 .............................................................................................................................................. www.ti.com Remote temperature sensing on the TMP441/42 measures very small voltages using very low currents; therefore, noise at the IC inputs must be minimized. Most applications using the TMP441/42 will have high digital content, with several clocks and logic level transitions creating a noisy environment. Layout should adhere to the following guidelines: 1. Place the TMP441/42 as close to the remote junction sensor as possible. 2. Route the DXP and DXN traces next to each other and shield them from adjacent signals through the use of ground guard traces, as shown in Figure 19. If a multilayer PCB is used, bury these traces between ground or VDD planes to shield them from extrinsic noise sources. 5 mil (0.005 in, or 0,127 mm) PCB traces are recommended. 3. Minimize additional thermocouple junctions Figure 19. Suggested PCB Layer Cross-Section caused by copper-to-solder connections. If these junctions are used, make the same number and approximate locations of copper-to-solder connections in both the DXP and DXN connections to cancel any thermocouple effects. 4. Use a 0.1 µF local bypass capacitor directly between the V+ and GND of the TMP441/42, as shown in Figure 20. Minimize filter capacitance between DXP and DXN to 330pF or less for optimum measurement performance. This capacitance includes any cable capacitance between the remote temperature sensor and TMP441/42. 5. If the connection between the remote temperature sensor and the TMP441/42 is less than 8 in (20,32 cm) long, use a twisted-wire pair connection. Beyond 8 in, use a twisted, shielded pair with the shield grounded as close to the TMP441/42 as possible. Leave the remote sensor connection end of the shield wire open to avoid ground loops and 60Hz pickup. 6. Thoroughly clean and remove all flux residue in and around the pins of the TMP441/42 to avoid temperature offset readings as a result of leakage paths between DXP or DXN and GND, or between DXP or DXN and V+. Figure 20. Suggested Bypass Capacitor Placement and Trace Shielding 22 Submit Documentation Feedback Copyright © 2008–2009, Texas Instruments Incorporated Product Folder Link(s): TMP441 TMP442 |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |