| 数据搜索系统,热门电子元器件搜索 |
|
TMP100NA/3K 数据表(PDF) 14 Page - Texas Instruments |
|
|
|
|||||||||||||||||||||||||||||
TMP100NA/3K 数据表(HTML) 14 Page - Texas Instruments |
|
14 / 30 page ![]() Frame 1 SMBus ALERT Response Address Byte Frame 2 Slave Address From TMP100 Start By Master ACK By TMP100 or TMP101 From TMP100 orTMP101 NACK By Master Stop By Master 1 9 1 9 SDA SCL ALERT 0 0 0 1 1 0 0 R/W 1 0 0 1 A2 A1 A0 S ta tu s TMP100, TMP101 SBOS231I – JANUARY 2002 – REVISED NOVEMBER 2015 www.ti.com Figure 9. Timing Diagram for SMBus ALERT 7.4 Device Functional Modes 7.4.1 Shutdown Mode (SD) The Shutdown Mode of the TMP100 and TMP101 devices lets the user save maximum power by shutting down all device circuitry other than the serial interface, which reduces current consumption to less than 1 µA. For the TMP100 and TMP101 devices, Shutdown Mode is enabled when the SD bit is 1. The device shuts down when the current conversion is completed. For SD equal to 0, the device maintains continuous conversion. 7.4.2 OS/ALERT (OS) The TMP100 and TMP101 devices feature a One-Shot Temperature Measurement Mode. When the device is in Shutdown Mode, writing 1 to the OS/ALERT bit starts a single temperature conversion. The device returns to the shutdown state at the completion of the single conversion. This feature is useful to reduce power consumption in the TMP100 and TMP101 devices when continuous monitoring of temperature is not required. Reading the OS/ALERT bit provides information about the Comparator Mode status. The state of the POL bit inverts the polarity of data returned from the OS/ALERT bit. For POL = 0, the OS/ALERT reads as 1 until the temperature equals or exceeds THIGH for the programmed number of consecutive faults, causing the OS/ALERT bit to read as 0. The OS/ALERT bit continues to read as 0 until the temperature falls below TLOW for the programmed number of consecutive faults when the OS/ALERT bit again reads as 1. The status of the TM bit does not affect the status of the OS/ALERT bit. 7.4.3 Thermostat Mode (TM) The Thermostat Mode bit of the TMP101 device indicates to the device whether to operate in Comparator Mode (TM = 0) or Interrupt Mode (TM = 1). For more information on comparator and interrupt modes, see the High- and Low-Limit Registers section. 7.4.3.1 Comparator Mode (TM = 0) In Comparator Mode (TM = 0), the ALERT pin is activated when the temperature equals or exceeds the value in the THIGH register and remains active until the temperature falls below the value in the TLOW register. For more information on the Comparator Mode, see the High- and Low-Limit Registers section. 7.4.3.2 Interrupt Mode (TM = 1) In Interrupt Mode (TM = 1), the ALERT pin is activated when the temperature exceeds THIGH or goes below the TLOW registers. The ALERT pin is cleared when the host controller reads the temperature register. For more information on the interrupt mode, see the High- and Low-Limit Registers section. 14 Submit Documentation Feedback Copyright © 2002–2015, Texas Instruments Incorporated Product Folder Links: TMP100 TMP101 |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |