48 / 64 page ![]() E5EZ-PRR 48 Alarm Types • Alarm outputs are determined by a combination of “alarm type,” “alarm value,” and “alarm hysteresis” alarm output conditions. • This section describes the “alarm type,” “alarm value,” “upper-limit alarm” and “lower-limit alarm” parameters. 0 Alarm function OFF Output OFF 1 See note 1. Upper-and lower-limit See note 2. Upper-limit 2 3 Lower-limit 4 See note 1. Upper-and lower-limit range See note 3. Upper-and lower-limit with standby sequence 5 See note 1. See note 4. (See note 5) Upper-limit with standby sequence 6 Lower-limit with standby sequence 7 Absolute-value upper-limit 8 Absolute-value lower-limit 9 Absolute-value upper-limit with standby sequence 10 Absolute-value lower-limit with standby sequence 11 ON OFF L H SP X ON OFF SP X ON OFF SP X SP ON OFF X ON OFF SP X ON OFF SP X ON OFF SP X ON OFF SP ON OFF L H SP ON OFF L H SP X ON OFF 0 X ON OFF 0 X ON OFF 0 X ON OFF 0 X ON OFF 0 X ON OFF 0 X ON OFF 0 X ON OFF 0 SP ON OFF X L H SP SP L H L SP H H LSP SP H L H< 0.L >0 |H| < |L| H> 0.L <0 |H| > |L| Case 1 Case 2 Case 3 (Always ON) H< 0.L >0 |H| < |L| H> 0.L <0 |H| > |L| H< 0.L <0 L H SP SP L H L SP H H L SP SP H L 3. Set value: 4 (Upper-and lower-limit range) 2. Set value: 1 (Upper-and lower-limit alarm) Case 1 Case 2 Case 3 (Always OFF) 4. Set value: 5 (Upper-and lower-limit with standby sequence) 5. Set value: 5 (Upper-and lower-limit with standby sequence) Alarm 1 Type 2 Alarm output operation Set values Type When X is positive When X is negative Note 1. Upper and lower-limit values can be set independently for each alarm type, and are expressed as L and H. The set values are 1, 4, and 5. If there are any overlaps in the upper and lower limits for hysteresis, the alarm will always be OFF. There are alarm types 1 to 2 (initial setting level), and settings should be made independently for each alarm. The default is 2: upper limit. alt1 2 l.ini H< 0.L <0 |H| ≥ |L| H< 0.L <0 |H| ≤ |L| H < 0, L < 0 H < 0, L > 0 |H| ≥ |L| H > 0, L < 0 |H| ≤ |L| • The upper and lower limit alarms described above. • In cases 1 and 2, if there is significant overlap between the upper and lower limit values after hysteresis, the alarm will always be OFF. Examples of case 1 and 2: In case 3, under general conditions, the alarm is turned OFF. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |