31 / 56 page ![]() H7CX-A @-N 31 Tachometer NPN/PNP Input Mode ( imod)★ Select either NPN input (no-voltage input) or PNP input (voltage input) as the input format. When using a two-wire sensor, select NPN input. The same setting is used for all external inputs. For details on input connections, refer to Input Connections on page page 9. Display Color ( colr) Set the color used for the measurement value. *1. If the tachometer output mode is set to AREA, however, the measured value is displayed in red when control output 1 is OFF and in green when control output 1 is ON. *2. If the tachometer output mode is set to AREA, however, the measured value is displayed in green when control output 1 is OFF and in red when control output 1 is ON. *3. If the tachometer output mode is set to AREA, however, the measured value is displayed in red when control output 1 is OFF and in orange when control output 1 is ON. *4. If the tachometer output mode is set to AREA, however, the measured value is displayed in orange when control output 1 is OFF and in red when control output 1 is ON. *5. If the tachometer output mode is set to AREA, however, the measured value is displayed in green when control output 1 is OFF and in orange when control output 1 is ON. *6. If the tachometer output mode is set to AREA, however, the measured value is displayed in orange when control output 1 is OFF and in green when control output 1 is ON. Peak/bottom Hold Enabled ( dhld) This function records the peak and bottom (i.e., minimum) after counting starts (after turning ON the power supply or changing the configuration selection mode or function setting). The peak value is also held when the power supply is interrupted. Output Hysteresis ( hys) This setting can be used to prevent output chattering if the measurement value fluctuates slightly near the set value. The measurement value after prescaling is set. Output OFF Delay ( offd) This function delays the timing for turning OFF comparative output by a certain time. The ON time can be held for the set time if the comparative result changes in a short time. Operation will continue and outputs will not change when holding the value. Set Value Upper Limit ( pl-h) Set the upper limit for the set value when it is set in run mode. The limit can be set to between 1 and 999999. Output Allocation ( otst) When using an H7CX-AU @-N model as 2-stage counter, each output can be flexibly allocated to either stage 1 or 2. The transistor output can be allocated to SV1 and the contact output to SV2 or vice verse, as in the following tables. H7CX-AU-N/-AUD1-N H7CX-AUSD1-N Key Protect Level ( kypt) Set the key protect level. Refer to Key Protect Level on page page 36. Pulse Cycle Measurement/Pulse Width Measurement ( calm) Set the measurement mode to pulse cycle measurement or pulse width measurement. With pulse cycle measurement, the number of pulse cycles that occur in 1 s is measured. With pulse width measurement, the ON time for one pulse is measured. An input OFF period of at least 20 ms is required for pulse width measurement. If there is no input pulse during pulse width measurement, the previously measured value will be held. Display Unit ( unit) When pulse cycle measurement is used, set the display unit to Hz (hertz) or s (seconds). Counting Interval ( intv) If the measurement speed is 10 kHz when pulse cycle measurement is used, set the measurement interval to 200 ms or Cont (10 ms min.). Control output OFF Control output ON red Red (fixed) grn Green (fixed) org Orange (fixed) r-g *1 Measured value is displayed in red when both control outputs 1 and 2 are OFF. Measured value is displayed in green when either control output 1 or control output 2 is ON. g-r *2 Measured value is displayed in green when both control outputs 1 and 2 are OFF. Measured value is displayed in red when either control output 1 or control output 2 is ON. r-o *3 Measured value is displayed in red when both control outputs 1 and 2 are OFF. Measured value is displayed in orange when both control outputs 1 and 2 are OFF. o-r *4 Measured value is displayed in orange when both control outputs 1 and 2 are OFF. Measured value is displayed in red when both control outputs 1 and 2 are OFF. g-o *5 Measured value is displayed in green when both control outputs 1 and 2 are OFF. Measured value is displayed in orange when both control outputs 1 and 2 are OFF. o-g *6 Measured value is displayed in orange when both control outputs 1 and 2 are OFF. Measured value is displayed in green when both control outputs 1 and 2 are OFF. Output 1 Output 2 off Transistor (12-13) Contact (3, 4, 5) on Contact (3, 4, 5) Transistor (12-13) Output 1 Output 2 off Transistor (12-13) Transistor with diode (3, 4, 5) on Transistor with diode (3, 4, 5) Transistor (12-13) OUTX1 OUTY2 Display value Comparison value 2 Hysteresis Hysteresis Comparison value 1 Set the hysteresis for when the output turns OFF. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |