| 数据搜索系统,热门电子元器件搜索 |
|
PAC1921 数据表(PDF) 30 Page - Microchip Technology |
|
|
|||||||||||||||||||||||||||||
PAC1921 数据表(HTML) 30 Page - Microchip Technology |
|
30 / 56 page ![]() PAC1921 High-Side Current/Power Sensor Evaluation Board User’s Guide DS50002376A-page 30 2015 Microchip Technology Inc. To restart the communication between the software and the evaluation board, click the Run button. The arrow button disappears when the communications resume. To close the program, use the Close (X) button in the upper right corner of the window. 4.2.1.2 SMBus ADDRESS The “SMBus Address” box, shown in Figure 4-5, indicates the selected SMBus address. The SMBus address can be changed by moving a jumper (see Section 3.3.1 “SMBus Mode”). FIGURE 4-5: SMBus Address Indicator. 4.2.1.3 COM STATUS INDICATOR The “COM” status indicator, on the right side of the panel as shown in Figure 4-5, indicates the status of communications over the SMBus. During normal operation, the “COM” indicator is black. If the SMBus communications fail, the “COM” indicator turns red. 4.2.1.4 SINGLE READ/CONTINUOUS READ The panel defaults to continuous register reads (toggle switch in down position, as shown in Figure 4-5). To stop continuous register reads, check the “Enable Single Read” box. In order to capture the register values at a given time, click the switch, which will briefly flip to “Single Read”. 4.2.1.5 REGISTER CONTENT “Reg Content”, shown in Figure 4-3, is a scrollable list of the PAC1921 registers and the last read value. It is important to note that not all addresses are physical memory locations on the device; these registers will read ‘0’. Likewise, some registers shown (undocumented in the data sheet) may have data. Editing these registers can cause unexpected results. To update a register value, locate the register address in the left column, type the new value in the corresponding cell in the right column, and press Enter on the keyboard or click on another part of the GUI. Note 1: Stopping and restarting the GUI does not affect register settings. To restore default register settings, disconnect power from the evaluation board, then reconnect power. 2: Stopping the GUI clears the “Enable DC Vsense- Stimulus” box (see Section 4.2.6 “EVB Demo Configuration Panel”). SMBus Address Indicator COM Status Indicator Single Read Button |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |