| 数据搜索系统,热门电子元器件搜索 |
|
ECM40US24.. 数据表(PDF) 1 Page - XP Power Limited |
|
|
|||||||||||||||||||||||||||||
ECM40US24.. 数据表(HTML) 1 Page - XP Power Limited |
|
1 / 6 page ![]() Specification 40100 Watts • Compact Size • IT & Medical Approvals • Convectioncooled • Class I and II Construction • DC Input Version Available (DCM Series) • PoE Isolation Version Available (POE Series) • 3 Year Warranty ECM Series Input Input Voltage • 90-264 VAC (120-370 VDC) Input Frequency • 47-63 Hz; 440 Hz* Input Current • 40 W: 0.4 A max at 230 VAC 60 W: 0.6 A max at 230 VAC 100 W: 0.9 A max at 230 VAC Inrush Current • 40 A max at 230 VAC Earth Leakage Current • <125 µA at 115 VAC/60 Hz <210 µA at 230 VAC/50 Hz Power Factor • EN61000-3-2 Input Protection • Internal T3.15 A, 250 V fuse in line and neutral Output Output Voltage • See tables Output Voltage Trim • ±5% on 3.3 V & 5 V versions, ±10% on other single output models and V1 of multi-output models. (See note 1 for ECM40/60 models) Initial Set Accuracy • ±1.0% V1, ±5% V2, V3 & V4 Minimum Load • See tables Start Up Delay • 1.5 s max Start Up Rise Time • 10 ms max Hold Up Time • 16/75 ms min at 115/230 VAC Line Regulation • ±0.5% Load Regulation • ±1% single output models; ±3% V1, ±5% V2 & V3 ECM40/60 multi-output models. ±1% V1 & V2, ±5% V3 & V4 ECM100 Cross Regulation • 2% on ECM40/60 only Over/Undershoot • None at turn on/off Transient Response • 4% max. deviation, recovery to within 1% in 500 µs for a 25% load change Ripple & Noise • 1% pk-pk, 20 MHz bandwidth Overvoltage Protection • 115-135% Vnom, recycle input to reset Overload Protection • 110-150% on primary power limit, auto recovery Short Circuit Protection • Trip and restart (hiccup mode) Temperature • 0.05%/°C Coefficient Peak Load • 120% for 100 ms ECM40/60 (see note 3) * Safety approvals cover frequency range 47-63 Hz xppower.com General Efficiency • 80-85% depending on model Isolation • 4000 VAC Input to Output 2 x MOPP ECM100 single output models, 1 x MOPP ECM100 multi output and all ECM40/60 models (contact sales for 2 x MOPP), 1500 VAC Input to Ground 1 x MOPP, 500 VAC Output to Ground Switching Frequency • 70 kHz typical Power Density • 40 W: 4.2 W/In3 60 W: 6.3 W/In3 100 W: 7.4 W/In3 MTBF • 600 kHrs to MIL-HDBK-217F at 25 °C, GB Environmental Operating Temperature • 0 °C to +70 °C. Refer to derating curves for specific operating limitations. Cooling • Convection & fan-cooled ratings (see derating curves) Operating Humidity • 95% RH, non-condensing Storage Temperature • -40 °C to +85 °C Operating Altitude • 3000 m Shock • 30 g pk, half sine, 6 axes Vibration • 2 g rms, 5 Hz to 500 Hz, 3 axes EMC & Safety Emissions • EN60601-1-2, EN61204-3, FCC 20780, EN55022 & EN55011, level B conducted EN55022 Level A radiated Harmonic Currents • EN61000-3-2, class A Voltage Flicker • EN61000-3-3 ESD Immunity • EN61000-4-2, level 3 Perf Criteria A Radiated Immunity • EN61000-4-3, 10 V/m Perf Criteria A EFT/Burst • EN61000-4-4, level 3 Perf Criteria A Surge • EN61000-4-5, level 3 Perf Criteria A, SEMI F47 Conducted Immunity • EN61000-4-6, 10 V Perf Criteria A Dips & Interruptions • EN61000-4-11, 30% 10 ms, 60% 100 ms, 100% 5000 ms, Perf Criteria A, B, B EN60601-1, 30% 500 ms, 60% 100 ms, 100% 10 ms, 100% 5000 ms, Perf Criteria A, A (with 50% load), A, B Safety Approvals • EN60601-1, ANSI/AAMI ES60601-1, CSA22.2 No.60601-1 per cUL, Including Risk Management, EN60950-1, UL60950-1 |
类似零件编号 - ECM40US24.. |
|
类似说明 - ECM40US24.. |
|
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |