Back Button PDRV5033FAQDBZR Datasheet HTML 5Page - Texas Instruments PDRV5033FAQDBZR Datasheet HTML 6Page - Texas Instruments PDRV5033FAQDBZR Datasheet HTML 7Page - Texas Instruments PDRV5033FAQDBZR Datasheet HTML 8Page - Texas Instruments PDRV5033FAQDBZR Datasheet HTML 9Page - Texas Instruments PDRV5033FAQDBZR Datasheet HTML 10Page - Texas Instruments PDRV5033FAQDBZR Datasheet HTML 11Page - Texas Instruments PDRV5033FAQDBZR Datasheet HTML 12Page - Texas Instruments PDRV5033FAQDBZR Datasheet HTML 13Page - Texas Instruments Next Button
Zoom Inzoom in Zoom Outzoom out
 9 / 28 page
background image
Temperature
Compensation
Bias
+
±
Regulated Supply
Reference
Gate
Drive
OCP
VCC
OUT
GND
2.5 to 38 V
R1
C2
(Optional)
C1
Hall Element
9
DRV5033
www.ti.com
SLIS152E – MAY 2014 – REVISED FEBRUARY 2016
Product Folder Links: DRV5033
Submit Documentation Feedback
Copyright © 2014–2016, Texas Instruments Incorporated
7 Detailed Description
7.1 Overview
The DRV5033 device is a chopper-stabilized hall sensor with a digital omnipolar switch output for magnetic
sensing applications. The DRV5033 device can be powered with a supply voltage between 2.5 and 38 V, and will
survive –22 V reverse battery conditions continuously. Note that the DRV5033 device will not be operating when
about –22 to 2.4 V is applied to VCC (with respect to GND). In addition, the device can withstand voltages up to
40 V for transient durations.
The field polarity is defined as follows: a south pole near the marked side of the package is a positive magnetic
field. A north pole near the marked side of the package is a negative magnetic field.
The omnipolar configuration allows the hall sensor to respond to either a south or north pole. A strong magnetic
field of either polarity will cause the output to pull low (operate point, BOP), and a weaker magnetic field will cause
the output to release (release point, BRP). Hysteresis is included in between the operate and release points, so
magnetic field noise will not trip the output accidentally.
An external pullup resistor is required on the OUT pin. The OUT pin can be pulled up to VCC, or to a different
voltage supply. This allows for easier interfacing with controller circuits.
7.2 Functional Block Diagram



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28


数据表 下载

Go To PDF Page


链接网址



ALLDATASHEET是否为您带来帮助?  [ DONATE ] 

关于 Alldatasheet   |   广告服务   |   联系我们   |   隐私政策   |   数据表链接    |   链接交换   |   制造商名单
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com