12 / 28 page ![]() 12 ICS1702 When a high level is required, the pin must be tied to V DD . The voltage ranges for low (L), open (Z) and high (H) are listed in Table 10, DC Characteristics. To program the AUX0 and AUX1 inputs, refer to the Mode Select List in Table 5. See the section on Auxiliary Modes of Operation for additional information. Mode Selection: AUX0, AUX1 Pins The AUX0 and AUX1 inputs must be programmed by the user to inform the ICS1702 of the desired auxiliary mode. When left unconnected (open) these tri-level pins will float to about 2.3V. When a low level is required, the pin must be grounded. Table 5: Mode Select List Table 4: Charge Rate List SEL0 SEL1 Charge Rate Topping Charge pulse Rate Maintenance Charge Pulse Rate Fast Charge Timer Duration (after reset) L L 4C (15 min) one every 40 sec one every 160 sec 21 min L H 2C (30 min) one every 20 sec one every 80 sec 39 min L Z 1.3C (45 min) one every 13 sec one every 53 sec 57 min H L 1C (60 min) one every 10 sec one every 40 sec 75 min H Z C/1.5 (90 min) one every 7 sec one every 27 sec 110 min H H C/2 (120 min) one every 5 sec one every 20 sec 144 min Z L C/2.5 (150 min) one every 4 sec one every 16 sec 212 min Z Z C/3 (180 min) one every 3 sec one every 13 sec 244 min Z H C/4 (240 min) one every 2 sec one every 10 sec 275 min See the section on Controller Operation for additional information on the topping charge and maintenance charge. See the section on Charge Termination Methods for additional information on the charge timer. AUX0 AUX1 Mode Selected Mode Operation L L Charging System Test Charging system test for embedded applications L H Direct Maintenance Indefinite C/40 maintenance charge Z Z Fast Charge Default Z L Discharge-Only Battery discharge to 1V/cell H L Discharge-to-Charge Battery discharge to 1V/cell followed by the selected charge mode H Z Condition Timed C/10 topping charge followed by a C/40 maintenance charge H H Ten Hour Timer Limits total charge including the maintenance charge to 10 hours |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |