| 数据搜索系统,热门电子元器件搜索 |
|
CPC7592BA 数据表(PDF) 16 Page - IXYS Corporation |
|
|
|||||||||||||||||||||||||||||
CPC7592BA 数据表(HTML) 16 Page - IXYS Corporation |
|
16 / 19 page ![]() INTEGRATED CIRCUITS DIVISION 16 www.ixysic.com R04 CPC7592 the device to the all-off state and a high impedance (Z) state for normal operation. This requires the use of an open-collector or open-drain type buffer. 2.6 Ringing Switch Zero-Cross Current Turn Off After the application of a logic input to turn SW4 off, the ringing switch is designed to delay the change in state until the next zero-crossing. Once on, the switch requires a zero-current cross to turn off, and therefore should not be used to switch a pure DC signal. The switch will remain in the on state no matter the logic input until the next zero crossing. These switching characteristics will reduce and possibly eliminate overall system impulse noise normally associated with ringing switches. See IXYS IC Division’s application note AN-144, Impulse Noise Benefits of Line Card Access Switches for more information. The attributes of ringing switch SW4 may make it possible to eliminate the need for a zero-cross switching scheme. A minimum impedance of 300 in series with the ringing generator is recommended. 2.7 Power Supplies Both a +5 V supply and battery voltage are connected to the CPC7592. Switch state control is powered exclusively by the +5 V supply. As a result, the CPC7592 exhibits extremely low power consumption during active and idle states. Although battery power is not used for switch control, it is required to supply trigger current for the integrated internal protection circuitry SCR during fault conditions. This integrated SCR is designed to activate whenever the voltage at TBAT or RBAT drops 2 to 4 V below the applied voltage on the VBAT pin. Because the battery supply at this pin is required to source trigger current during negative overvoltage fault conditions at tip and ring, it is important that the net supplying this current be a low impedance path for high speed transients such as lightning. This will permit trigger currents to flow enabling the SCR to activate and thereby prevent a fault induced negative overvoltage event at the TBAT or RBAT nodes. 2.8 Battery Voltage Monitor The CPC7592 also uses the VBAT voltage to monitor battery voltage. If system battery voltage is lost, the CPC7592 immediately enters the all-off state. It remains in this state until the battery voltage is restored. The device also enters the all-off state if the battery voltage rises more positive than about –10 V with respect to ground and remains in the all-off state until the battery voltage drops below approximately –15 V with respect to ground. This battery monitor feature draws a small current from the battery (less than 1 A typical) and will add slightly to the device’s overall power dissipation. This monitor function performs properly if the CPC7592 and SLIC share a common battery supply origin. Otherwise, if battery is lost to the CPC7592 but not to the SLIC, then the VBAT pin will be internally biased by the potential applied at the TBAT or RBAT pins via the internal protection circuitry SCR trigger current path. 2.9 Protection 2.9.1 Diode Bridge/SCR The CPC7592 uses a combination of current limited break switches, a diode bridge/SCR clamping circuit, and a thermal shutdown mechanism to protect the SLIC device or other associated circuitry from damage during line transient events such as lightning. During a positive transient condition, the fault current is conducted through the diode bridge to ground via FGND. Voltage is clamped to a diode drop above ground. During a negative transient of 2 to 4 V more negative than the voltage source at VBAT, the SCR conducts and faults are shunted to FGND via the SCR or the diode bridge. In order for the SCR to crowbar (or foldback), the SCR’s on-voltage (see “Protection Circuitry Electrical Specifications” on page 9) must be less than the applied voltage at the VBAT pin. If the VBAT voltage is less negative than the SCR on-voltage or if the VBAT supply is unable to source the trigger current, the SCR will not crowbar. For power induction or power-cross fault conditions, the positive cycle of the transient is clamped to a diode drop above ground and the fault current directed to ground. The negative cycle of the transient will cause the SCR to conduct when the voltage exceeds the VBAT reference voltage by two to four volts, steering the fault current to ground. Note: The CPC7592xB does not contain the protection SCR but instead uses diodes to clamp both polarities of a transient fault. These diodes direct the negative potential’s fault current to the VBAT pin. |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |