| 数据搜索系统,热门电子元器件搜索 |
|
TSC2102 数据表(PDF) 21 Page - Texas Instruments |
|
|
|
|||||||||||||||||||||||||||||
TSC2102 数据表(HTML) 21 Page - Texas Instruments |
|
21 / 54 page ![]() TSC2102 SLAS379A− APRIL 2003 − REVISED JUNE 2004 www.ti.com 21 ADC VBAT 10 k Ω 2 k Ω R LDO or DC-DC Converter 2.7 V to 3.6 V VDD + − Battery 0.5 to 6 V Figure 17. Battery Measurement Functional Block Diagram Battery measurement can only be done in host controlled mode. See the section Conversion Time Calculation for the TSC2102 and subsection Non Touch Measurement Operation in this data sheet for timing diagrams and conversion time calculations. Auxiliary Measurement The auxiliary voltage input (AUX) can be measured in much the same way as the battery inputs. Applications might include external temperature sensing, ambient light monitoring for controlling the back-light, or sensing the current drawn from the battery. The auxiliary input can also be monitored continuously in scan mode. Auxiliary measurement can only be done in host controlled mode. See the section Conversion Time Calculation for the TSC2102 and subsection Non Touch Measurement Operation in this data sheet for timing diagrams and conversion time calculations. Port Scan If making measurements of BAT1, BAT2, and AUX is desired on a periodic basis, the port scan mode can be used. This mode causes the TSC2102 to sample and convert both battery inputs and the auxiliary input. At the end of this cycle, the battery and auxiliary result registers contain the updated values. Thus, with one write to the TSC2102, the host can cause three different measurements to be made. Port scan can only be done in host−controlled mode. See the section Conversion Time Calculation for the TSC2102 and subsection Port Scan Operation in this data sheet for timing diagrams and conversion time calculations. Hardware Reset The device requires hardware reset (active low) after power up. A hardware reset pulse initializes all the internal registers and counters. Hardware Power Down The device powers down all the internal circuitry to save power. All the register contents are maintained. Some counters maintain their value. The hardware power-down circuit also disables the pen-touch detect circuit. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |